Files
vuln-cve/data/2026/75xxx/CVE-2026-75940.json
T

203 lines
7.9 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-75940",
"assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"state": "PUBLISHED",
"assignerShortName": "lenovo",
"dateReserved": "2026-08-18T15:55:52.564Z",
"datePublished": "2026-09-10T21:00:05.611Z",
"dateUpdated": "2026-09-11T14:50:16.336Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
"shortName": "lenovo",
"dateUpdated": "2026-09-10T21:00:05.611Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-798",
"description": "CWE-798: Use of Hard-coded Credentials",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Lenovo",
"product": "Health Application",
"platforms": [
"Android"
],
"versions": [
{
"status": "affected",
"version": "0",
"lessThanOrEqual": "1.5.0",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:lenovo:health_application:*:*:android:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndExcluding": "1.5.0"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability was reported in Lenovo Health Android Application, distributed exclusively in the Chinese market, that could allow an attacker to access sensitive health-related information.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "A vulnerability was reported in Lenovo Health Android Application, distributed exclusively in the Chinese market, that could allow an attacker to access sensitive health-related information."
}
]
}
],
"references": [
{
"url": "https://iknow.lenovo.com.cn/detail/442248",
"tags": [
"vendor-advisory"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "CRITICAL",
"baseScore": 9.3,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:N/SC:N/SI:N/SA:N"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "NONE",
"baseSeverity": "CRITICAL",
"baseScore": 9.1,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Update Lenovo Health Android Application version to 1.5.0 or later.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Update Lenovo Health Android Application version to 1.5.0 or later."
}
]
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.0-beta"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-09-11T14:49:53.903558Z",
"id": "CVE-2026-75940",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-09-11T14:50:16.336Z"
}
}
]
}
}