148 lines
6.1 KiB
JSON
148 lines
6.1 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2026-6866",
|
|
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "schneider",
|
|
"dateReserved": "2026-04-22T16:17:46.134Z",
|
|
"datePublished": "2026-05-12T13:59:33.610Z",
|
|
"dateUpdated": "2026-05-12T15:43:40.858Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
|
|
"shortName": "schneider",
|
|
"dateUpdated": "2026-05-12T13:59:33.610Z"
|
|
},
|
|
"title": "Initialization of a Resource with an Insecure Default vulnerability on EcoStruxure™ Panel Server",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-1188",
|
|
"description": "CWE-1188 Initialization of a resource with an insecure default",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Schneider Electric",
|
|
"product": "EcoStruxure™ Panel Server",
|
|
"modules": [
|
|
"PAS400",
|
|
"PAS600",
|
|
"PAS600V2",
|
|
"PAS800",
|
|
"PAS800V2"
|
|
],
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "Versions 002.005.000 and prior"
|
|
}
|
|
],
|
|
"defaultStatus": "unaffected"
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials.",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "CWE-1188 Initialization of a Resource with an Insecure Default vulnerability exists that could cause unauthorized disclosure of sensitive information when credentials revert to initial settings in rare circumstances, enabling unauthorized authentication using known credentials."
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-132-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-132-04.pdf"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV4_0": {
|
|
"attackVector": "NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "PRESENT",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "HIGH",
|
|
"subConfidentialityImpact": "NONE",
|
|
"vulnIntegrityImpact": "NONE",
|
|
"subIntegrityImpact": "NONE",
|
|
"vulnAvailabilityImpact": "NONE",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"version": "4.0",
|
|
"baseSeverity": "HIGH",
|
|
"baseScore": 8.2,
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
|
|
}
|
|
}
|
|
],
|
|
"source": {
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"x_generator": {
|
|
"engine": "Vulnogram 1.0.2"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-05-12T15:43:29.539824Z",
|
|
"id": "CVE-2026-6866",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-05-12T15:43:40.858Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |