343 lines
15 KiB
JSON
343 lines
15 KiB
JSON
{
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.2",
|
||
"cveMetadata": {
|
||
"cveId": "CVE-2026-68967",
|
||
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"state": "PUBLISHED",
|
||
"assignerShortName": "icscert",
|
||
"dateReserved": "2026-08-10T16:03:40.497Z",
|
||
"datePublished": "2026-08-27T20:50:22.011Z",
|
||
"dateUpdated": "2026-08-28T14:13:53.649Z"
|
||
},
|
||
"containers": {
|
||
"cna": {
|
||
"providerMetadata": {
|
||
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"shortName": "icscert",
|
||
"dateUpdated": "2026-08-27T20:50:22.011Z"
|
||
},
|
||
"title": "Out-of-bounds Write in Bendix EC80 Brake ECU",
|
||
"datePublic": "2026-08-25T14:28:00.000Z",
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"cweId": "CWE-787",
|
||
"description": "CWE-787",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"affected": [
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP+ J1708",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z228999"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z300822"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP+ 6S/6M",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z228999"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z300822"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP+ PLC",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z228999"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z300822"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP+ 2nd CAN",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z228999"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z300822"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP+ Integrated TPMS",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z228999"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z300822"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP 6S/6M",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z266494"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z302578"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP PLC",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z266494"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z302578"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP 2nd CAN",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z266494"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z302578"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP CAN Gateway",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z266494"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z302578"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP 4S/4M",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z286098"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z302579"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
},
|
||
{
|
||
"vendor": "Bendix",
|
||
"product": "EC80ESP PLC",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "Z286098"
|
||
},
|
||
{
|
||
"status": "unaffected",
|
||
"version": "Z302579"
|
||
}
|
||
],
|
||
"defaultStatus": "unaffected"
|
||
}
|
||
],
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Bendix EC80 Brake ECU is vulnerable to an out-of-bounds write, which could allow an attacker \nto deliver a payload that could establish an arbitrary write primitive, \nwhich could crash the ECU.",
|
||
"supportingMedia": [
|
||
{
|
||
"type": "text/html",
|
||
"base64": false,
|
||
"value": "Bendix EC80 Brake ECU is vulnerable to an out-of-bounds write, which could allow an attacker \nto deliver a payload that could establish an arbitrary write primitive, \nwhich could crash the ECU."
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"references": [
|
||
{
|
||
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-237-05"
|
||
},
|
||
{
|
||
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-237-05.json"
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
],
|
||
"cvssV3_1": {
|
||
"version": "3.1",
|
||
"attackVector": "ADJACENT_NETWORK",
|
||
"attackComplexity": "LOW",
|
||
"privilegesRequired": "NONE",
|
||
"userInteraction": "NONE",
|
||
"scope": "UNCHANGED",
|
||
"confidentialityImpact": "NONE",
|
||
"integrityImpact": "HIGH",
|
||
"availabilityImpact": "NONE",
|
||
"baseSeverity": "MEDIUM",
|
||
"baseScore": 6.5,
|
||
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N"
|
||
}
|
||
},
|
||
{
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
],
|
||
"cvssV4_0": {
|
||
"attackVector": "ADJACENT",
|
||
"attackComplexity": "LOW",
|
||
"attackRequirements": "NONE",
|
||
"privilegesRequired": "NONE",
|
||
"userInteraction": "NONE",
|
||
"vulnConfidentialityImpact": "NONE",
|
||
"subConfidentialityImpact": "NONE",
|
||
"vulnIntegrityImpact": "HIGH",
|
||
"subIntegrityImpact": "NONE",
|
||
"vulnAvailabilityImpact": "NONE",
|
||
"subAvailabilityImpact": "NONE",
|
||
"exploitMaturity": "NOT_DEFINED",
|
||
"Safety": "NOT_DEFINED",
|
||
"Automatable": "NOT_DEFINED",
|
||
"Recovery": "NOT_DEFINED",
|
||
"valueDensity": "NOT_DEFINED",
|
||
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
||
"providerUrgency": "NOT_DEFINED",
|
||
"version": "4.0",
|
||
"baseSeverity": "HIGH",
|
||
"baseScore": 7.1,
|
||
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:N/SC:N/SI:N/SA:N"
|
||
}
|
||
}
|
||
],
|
||
"solutions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com. * EC80ESP+ J1708: Users should update their firmware to version Z300822.\n * EC80ESP+ 6S/6M: Users\n\n should update their firmware to version Z300822.\n * EC80ESP+ PLC: Users should update their firmware to version Z300822.\n * EC80ESP+ 2nd CAN:\nUsers should update their firmware to version Z300822.\n * EC80ESP+ Integrated TPMS: Users should update their firmware to version Z300822.\n * EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.\n * EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.\n * EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.\n * EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.",
|
||
"supportingMedia": [
|
||
{
|
||
"type": "text/html",
|
||
"base64": false,
|
||
"value": "Bendix recommends users update their firmware to the most recent firmware version releases. Users that need more help should contact Bendix directly at info@Bendix.com.<div><ul><li>EC80ESP+ J1708: Users should update their firmware to version Z300822.</li><li>EC80ESP+ 6S/6M: Users\n\n should update their firmware to version Z300822.</li><li>EC80ESP+ PLC: Users should update their firmware to version Z300822.</li><li>EC80ESP+ 2nd CAN:\nUsers should update their firmware to version Z300822.</li><li>EC80ESP+ Integrated TPMS: Users should update their firmware to version Z300822.</li><li>EC80ESP 6S/6M:\nUsers\nshould update their firmware to version Z302578.</li><li>EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302578.</li><li>EC80ESP 2nd CAN:\nUsers\n\nshould update their firmware to version Z302578.</li><li>EC80ESP CAN Gateway:\nUsers\n\nshould update their firmware to version Z302578.</li><li>EC80ESP 4S/4M:\nUsers\n\nshould update their firmware to version Z302579.</li><li>EC80ESP PLC:\nUsers\n\nshould update their firmware to version Z302579.</li></ul></div>"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"value": "Ben Gardiner of NMFTA reported this vulnerability to CISA.",
|
||
"type": "finder"
|
||
}
|
||
],
|
||
"source": {
|
||
"advisory": "ICSA-26-237-05",
|
||
"discovery": "EXTERNAL"
|
||
},
|
||
"x_generator": {
|
||
"engine": "Vulnogram 1.0.4"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"id": "CVE-2026-68967",
|
||
"role": "CISA Coordinator",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "partial"
|
||
}
|
||
],
|
||
"version": "2.0.3",
|
||
"timestamp": "2026-08-28T13:56:16.152994Z"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2026-08-28T14:13:53.649Z"
|
||
}
|
||
}
|
||
]
|
||
}
|
||
} |