Files
vuln-cve/data/2026/66xxx/CVE-2026-66875.json
T

213 lines
9.2 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-66875",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2026-08-03T16:54:56.466Z",
"datePublished": "2026-08-11T21:31:42.708Z",
"dateUpdated": "2026-08-12T12:48:32.842Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2026-08-11T21:31:42.708Z"
},
"title": "Mira Hormone Monitor, Mira Android App Missing authentication for critical function",
"datePublic": "2026-08-11T17:00:00.000Z",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-306",
"description": "CWE-306",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Quanovate Tech Inc. (operating as Mira / Mira Care)",
"product": "Mira Firmware",
"versions": [
{
"status": "affected",
"version": "1.7.1.47",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "01.07.01.53"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Quanovate Tech Inc. (operating as Mira / Mira Care)",
"product": "Mira Android App",
"platforms": [
"Android"
],
"versions": [
{
"status": "affected",
"version": "4.5.15.4",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "4.5.18"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "In the Mira hormone monitor device firmware v1.7.1.47 build 01070147, a remote unauthenticated attacker within BLE range (approximately 10–30 meters) can silently rebind the device to an attacker-controlled account, extract stored hormone measurements in cleartext, cause a denial-of-service via malformed or undocumented command opcodes, and passively track the user via a static random BLE address that never rotates.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "In the Mira hormone monitor device firmware v1.7.1.47 build 01070147, a remote unauthenticated attacker within BLE range (approximately 10–30 meters) can silently rebind the device to an attacker-controlled account, extract stored hormone measurements in cleartext, cause a denial-of-service via malformed or undocumented command opcodes, and passively track the user via a static random BLE address that never rotates."
}
]
}
],
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-223-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsma-26-223-01.json"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "ADJACENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 8.7,
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "HIGH",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Users should update the Mira app to the latest version iOS v3.5.18 / Android v4.5.18. Firmware v01.07.01.53 is updated via the app when the device is connected. No additional action is required.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Users should update the Mira app to the latest version iOS v3.5.18 / Android v4.5.18. Firmware v01.07.01.53 is updated via the app when the device is connected. No additional action is required."
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Gigi Xiaoqing Liu, Muzzammil Mohammed, Narmina Karimova, and En Mong of Northeastern University SPQR Lab reported this vulnerability to Quanovate Tech.",
"type": "finder"
}
],
"source": {
"advisory": "ICSMA-26-223-01",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-08-12T12:47:59.287111Z",
"id": "CVE-2026-66875",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-08-12T12:48:32.842Z"
}
}
]
}
}