"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-61892",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2026-07-16T16:04:55.185Z",
"datePublished": "2026-07-24T22:16:58.155Z",
"dateUpdated": "2026-07-27T14:31:09.468Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2026-07-24T22:16:58.155Z"
},
"title": "Weintek cMT3092X Incorrect Permission Assignment for Critical Resource",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-732",
"description": "CWE-732",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Weintek",
"product": "cMT3092X firmware",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "20210218",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "Weintek",
"product": "EasyWeb",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "v2.1.20",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "2.3.17-typeb"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<span>Weintek cMT3092X HMI allows a non-privileged user to modify tokens to escalate privileges.</span>"
}
]
}
],
"references": [
{
"url": "https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-204-03"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-204-03.json"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "HIGH",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 8.7,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support ( https://www.weintek.com/globalw/Support/Knowledge.aspx ) or from distributors.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<span>Weintek recommends users apply the patch package named cmt_typeB_20260316_007.patch, which contains a newer EasyWeb 2.3.17-typeb. This fix will be delivered as a patch-only update; no separate standard firmware release is planned. Users may request the patch directly from Weintek support (</span><a href=\"https://www.weintek.com/globalw/Support/Knowledge.aspx\">https://www.weintek.com/globalw/Support/Knowledge.aspx</a><span>) or from distributors.</span><br><br>"
}
]
},
{
"lang": "en",
"value": "Weintek has published a document with more details about this issue at: \n https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<span>Weintek has published a document with more details about this issue at:&nbsp;</span><br><a href=\"https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf\">https://dl.weintek.com/public/Document/TEC/TEC25003E_cMT_EasyWeb_V2_Security_Issues.pdf</a>"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Vincenzo Giuseppe Colacino of Secoore reported this vulnerability to CISA.",
"type": "finder"
}
],
"source": {
"advisory": "ICSA-26-204-03",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-07-27T14:30:54.856897Z",
"id": "CVE-2026-61892",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-07-27T14:31:09.468Z"
}
}
]
}
}