"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-60063",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2026-07-09T15:00:24.526Z",
"datePublished": "2026-07-16T19:59:16.196Z",
"dateUpdated": "2026-07-17T13:25:08.344Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2026-07-16T19:59:16.196Z"
},
"title": "AutomationDirect Productivity Suite Out-of-bounds Write",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-787",
"description": "CWE-787",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "AutomationDirect",
"product": "Productivity Suite",
"versions": [
{
"status": "affected",
"version": "0",
"lessThanOrEqual": "v4.6.2.2",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "v4.7.0.47"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "An out-of-bounds write vulnerability in the Productivity Suite allows a \nlocal attacker to trigger kernel memory corruption via a crafted IOCTL \nrequest, potentially resulting in privilege escalation or system \ninstability.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "An out-of-bounds write vulnerability in the Productivity Suite allows a \nlocal attacker to trigger kernel memory corruption via a crafted IOCTL \nrequest, potentially resulting in privilege escalation or system \ninstability."
}
]
}
],
"references": [
{
"url": "https://www.automationdirect.com/support/software-downloads"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-197-04"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-197-04.json"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "HIGH",
"baseScore": 7,
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "LOCAL",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 7.3,
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"workarounds": [
{
"lang": "en",
"value": "If the update cannot be applied right away, the following \ncompensating controls are recommended until the upgrade can be \nperformed.\n\n\n * Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure.\n * Use only trusted, dedicated internal networks or air-gapped systems for device communication.\n * Restrict both physical and logical access to authorized personnel only.\n * Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.\n * Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.\n * Enable and regularly review system logs to detect suspicious or unauthorized activity.\n * Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.\n * Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<p>If the update cannot be applied right away, the following \ncompensating controls are recommended until the upgrade can be \nperformed.<br></p><ul><li>Disconnect the engineering workstation from external networks (e.g., the internet or corporate LAN) to reduce exposure.</li><li>Use only trusted, dedicated internal networks or air-gapped systems for device communication.</li><li>Restrict both physical and logical access to authorized personnel only.</li><li>Configure whitelisting so that only trusted, pre-approved applications are allowed to run. Block any unauthorized software.</li><li>Use antivirus or EDR tools and configure host-based firewalls to block unauthorized access attempts.</li><li>Enable and regularly review system logs to detect suspicious or unauthorized activity.</li><li>Maintain secure, tested backups of the PLC and its configurations to minimize downtime in case of an incident.</li><li>Continuously evaluate risks associated with running outdated firmware and adjust compensating measures accordingly.</li></ul>"
}
]
}
],
"solutions": [
{
"lang": "en",
"value": "AutomationDirect recommends that users update Productivity suite to \nv4.7.0.47 and above \n https://www.automationdirect.com/support/software-downloads",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "AutomationDirect recommends that users update Productivity suite to \nv4.7.0.47 and above&nbsp;<br><a href=\"https://www.automationdirect.com/support/software-downloads\">https://www.automationdirect.com/support/software-downloads</a>"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Luca Borzacchiello of Nozomi Networks reported this vulnerability to CISA.",
"type": "finder"
}
],
"source": {
"advisory": "ICSA-26-197-04",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-07-17T13:24:44.620879Z",
"id": "CVE-2026-60063",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-07-17T13:25:08.344Z"
}
}
]
}
}