"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2026-42805",
|
|
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "bosch",
|
|
"dateReserved": "2026-04-30T08:03:11.875Z",
|
|
"datePublished": "2026-09-10T09:04:09.212Z",
|
|
"dateUpdated": "2026-09-10T15:01:26.029Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
|
|
"shortName": "bosch",
|
|
"dateUpdated": "2026-09-10T09:04:09.212Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c). \r\n\r\nThe function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info->data_ptr[0]) without enforcing bounds checks or clamping the value.\r\n\r\nWhen copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary. \r\n\r\nThis memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Bosch Sensortec",
|
|
"product": "BHI385 SensorAPI (C Library)",
|
|
"versions": [
|
|
{
|
|
"version": "1.1.0",
|
|
"status": "affected",
|
|
"versionType": "custom",
|
|
"lessThanOrEqual": "2.1.0"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en-US",
|
|
"description": "CWE-121 Stack-based Buffer Overflow",
|
|
"cweId": "CWE-121"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
|
|
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.4,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-09-10T15:01:13.115369Z",
|
|
"id": "CVE-2026-42805",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-09-10T15:01:26.029Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |