Files
vuln-cve/data/2026/42xxx/CVE-2026-42804.json
T

114 lines
5.2 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-42804",
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"state": "PUBLISHED",
"assignerShortName": "bosch",
"dateReserved": "2026-04-30T08:03:11.875Z",
"datePublished": "2026-09-10T08:56:14.315Z",
"dateUpdated": "2026-09-10T15:01:55.301Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch",
"dateUpdated": "2026-09-10T08:56:14.315Z"
},
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI360 SensorAPI(C-Library) in versions up to and including commit d6b200416a.\r\n\r\nThe vulnerability is located within the FIFO parsing and debug logging subsystem inside the function bhi360_parse_debug_message() in bhi360_parse.c (lines 1852-1875). \r\n\r\nThe parser trusts the first payload byte of a debug frame as the message length (msg_length) and copies that many bytes into a fixed-size 17-byte stack buffer (debug_msg) via memcpy without performing any bounds checking.\r\n\r\nA locally or physically positioned attacker (e.g., via a malicious sensor, counterfeit hardware module, or a Man-in-the-Middle on the communication bus) can exploit this vulnerability by injecting a crafted debug frame with a length byte exceeding 16.\r\n\r\nThis corrupts adjacent stack data, including the saved return address.\r\n\r\nFurthermore, because the overflowed buffer is subsequently passed to a printf-style logging sink, the attacker can supply format string specifiers (e.g., %n) to execute arbitrary code on the host microcontroller/SoC or cause a reliable system crash (Denial of Service)."
}
],
"affected": [
{
"vendor": "Bosch Sensortec",
"product": "BHI360_SensorAPI (C-Library)",
"versions": [
{
"version": "2.1.0",
"status": "affected",
"versionType": "custom",
"lessThanOrEqual": "2.2.0"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en-US",
"description": "CWE-121 Stack-based Buffer Overflow",
"cweId": "CWE-121"
}
]
}
],
"references": [
{
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
]
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseScore": 7.6,
"baseSeverity": "HIGH"
}
}
]
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-09-10T15:01:43.170911Z",
"id": "CVE-2026-42804",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-09-10T15:01:55.301Z"
}
}
]
}
}