Files
vuln-cve/data/2026/3xxx/CVE-2026-3508.json
T

158 lines
6.3 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-3508",
"assignerOrgId": "54bf65a7-a193-42d2-b1ba-8e150d3c35e1",
"state": "PUBLISHED",
"assignerShortName": "ASUS",
"dateReserved": "2026-03-04T05:51:48.969Z",
"datePublished": "2026-05-08T02:00:53.822Z",
"dateUpdated": "2026-09-17T08:32:29.783Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "54bf65a7-a193-42d2-b1ba-8e150d3c35e1",
"shortName": "ASUS",
"dateUpdated": "2026-09-17T08:32:29.783Z"
},
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "ASUS",
"product": "ASUS System Control Interface",
"versions": [
{
"status": "affected",
"version": "through V3.1.59.1",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:asus:asus_system_control_interface:through_v3.1.59.1:*:*:*:*:*:*:*"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Out-of-bounds Read vulnerability in the IOCTL handler in ASUS System Control Interface allows a local user to cause system crash (BSOD) via a read size that exceeds the buffer size.Refer to the '\nSecurity Update for MyASUS ' section on the ASUS Security Advisory for more information.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "An Out-of-bounds Read vulnerability in the IOCTL handler in ASUS System Control Interface allows a local user to cause system crash (BSOD) via a read size that exceeds the buffer size.<div>Refer to the '\nSecurity Update for MyASUS&nbsp;' section on the ASUS Security Advisory for more information.</div>"
}
]
}
],
"references": [
{
"url": "https://www.asus.com/security-advisory"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "MEDIUM",
"baseScore": 6.8,
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-05-08T13:01:59.967094Z",
"id": "CVE-2026-3508",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-05-08T13:02:09.176Z"
}
}
]
}
}