Files
vuln-cve/data/2026/39xxx/CVE-2026-39453.json
T

206 lines
9.0 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-39453",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2026-04-08T19:28:49.591Z",
"datePublished": "2026-10-09T14:42:18.998Z",
"dateUpdated": "2026-10-11T17:05:28.474Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2026-10-09T14:42:18.998Z"
},
"title": "Red Lion Controls N-Tron 700 Series Reachable Assertion",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-617",
"description": "CWE-617",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Red Lion Controls",
"product": "700 Series",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "Firmware Versions 3.11.0",
"versionType": "custom"
},
{
"status": "affected",
"version": "0",
"lessThan": "Bootloader Versions 2.0.6.1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "3.11.1"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "Navigating to a certain URL on the switch’s web server causes the switch to reboot. This can be automated using a tool like curl to create DoS conditions where the switch constantly reboots.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Navigating to a certain URL on the switch’s web server causes the switch to reboot. This can be automated using a tool like curl to create DoS conditions where the switch constantly reboots."
}
]
}
],
"references": [
{
"url": "https://www.hms-networks.com/"
},
{
"url": "https://www.hms-networks.com/cybersecurity"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "HIGH",
"baseScore": 8.3,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:H/A:H"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "LOW",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "LOW",
"subConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 8.5,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:H/VA:H/SC:L/SI:H/SA:H"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Red Lion controls recommends the following upgrades for the N-Tron 700 Series: \n\n\n * Upgrade to firmware version 3.11.1 or greater\n * Configure or disable the SNMP communities\n * Disable access to the web GUI\n\n\n\n\n\nThe upgrade procedure document can be viewed here https://www.hms-networks.com/ .\n\n\n\n\nThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<p>Red Lion controls recommends the following upgrades for the N-Tron 700 Series: <br></p><ul><li>Upgrade to firmware version 3.11.1 or greater</li><li>Configure or disable the SNMP communities</li><li>Disable access to the web GUI</li></ul>\n<p>The upgrade procedure document can be viewed <a href=\"https://www.hms-networks.com/\">here</a>.</p>\n<p>The advisory issued by HMS Networks regarding these vulnerabilities can be viewed <a href=\"https://www.hms-networks.com/cybersecurity\">here</a>.</p>"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA.",
"type": "finder"
}
],
"source": {
"advisory": "ICSA-26-281-01",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2026-39453",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"version": "2.0.3",
"timestamp": "2026-10-11T16:49:22.992241Z"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-10-11T17:05:28.474Z"
}
}
]
}
}