"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-35072",
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"state": "PUBLISHED",
"assignerShortName": "dell",
"dateReserved": "2026-04-01T05:04:41.954Z",
"datePublished": "2026-04-17T10:48:48.167Z",
"dateUpdated": "2026-10-14T14:13:43.751Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell",
"dateUpdated": "2026-10-14T14:13:43.751Z"
},
"datePublic": "2026-04-15T18:30:00.000Z",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Dell",
"product": "PowerProtect Data Domain",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "8.6.1.10, 8.7.0.1 or later",
"versionType": "semver"
},
{
"status": "affected",
"version": "0",
"lessThan": "8.3.1.30 or later",
"versionType": "semver"
},
{
"status": "affected",
"version": "0",
"lessThan": "7.13.1.70 or later",
"versionType": "semver"
},
{
"status": "affected",
"version": "0",
"lessThan": "2.7.9 with DD OS 8.3.1.30",
"versionType": "semver"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization\n of special elements used in an OS command ('OS command injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Dell PowerProtect Data Domain, versions 7.7.1.0 through 8.6.0.0 and version 8.7.0.0, LTS2025 release versions 8.3.1.0 through 8.3.1.20, LTS2024 release versions 7.13.1.0 through 7.13.1.60 contain an improper neutralization\n of special elements used in an OS command ('OS command injection') vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to arbitrary command execution with root privileges."
}
]
}
],
"references": [
{
"url": "https://www.dell.com/support/kbdoc/en-us/000450699/dsa-2026-060-security-update-for-dell-powerprotect-data-domain-multiple-vulnerabilities",
"tags": [
"vendor-advisory"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "LOCAL",
"attackComplexity": "LOW",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "MEDIUM",
"baseScore": 6.7,
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H"
}
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.1"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-04-17T00:00:00+00:00",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3",
"id": "CVE-2026-35072"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-04-18T03:55:38.963Z"
}
}
]
}
}