Files
vuln-cve/data/2026/34xxx/CVE-2026-34766.json
T

130 lines
5.5 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-34766",
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"state": "PUBLISHED",
"assignerShortName": "GitHub_M",
"dateReserved": "2026-03-30T19:54:55.554Z",
"datePublished": "2026-04-03T23:35:10.204Z",
"dateUpdated": "2026-04-06T19:07:15.349Z"
},
"containers": {
"cna": {
"title": "Electron: USB device selection not validated against filtered device list",
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-862",
"lang": "en",
"description": "CWE-862: Missing Authorization",
"type": "CWE"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"references": [
{
"name": "https://github.com/electron/electron/security/advisories/GHSA-9899-m83m-qhpj",
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/electron/electron/security/advisories/GHSA-9899-m83m-qhpj"
}
],
"affected": [
{
"vendor": "electron",
"product": "electron",
"versions": [
{
"version": "< 38.8.6",
"status": "affected"
},
{
"version": ">= 39.0.0-alpha.1, < 39.8.0",
"status": "affected"
},
{
"version": ">= 40.0.0-alpha.1, < 40.7.0",
"status": "affected"
},
{
"version": ">= 41.0.0-alpha.1, < 41.0.0-beta.8",
"status": "affected"
}
]
}
],
"providerMetadata": {
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M",
"dateUpdated": "2026-04-03T23:35:10.204Z"
},
"descriptions": [
{
"lang": "en",
"value": "Electron is a framework for writing cross-platform desktop applications using JavaScript, HTML and CSS. Prior to versions 38.8.6, 39.8.0, 40.7.0, and 41.0.0-beta.8, the select-usb-device event callback did not validate the chosen device ID against the filtered list that was presented to the handler. An app whose handler could be influenced to select a device ID outside the filtered set would grant access to a device that did not match the renderer's requested filters or was listed in exclusionFilters. The WebUSB security blocklist remained enforced regardless, so security-sensitive devices on the blocklist were not affected. The practical impact is limited to apps with unusual device-selection logic. This issue has been patched in versions 38.8.6, 39.8.0, 40.7.0, and 41.0.0-beta.8."
}
],
"source": {
"advisory": "GHSA-9899-m83m-qhpj",
"discovery": "UNKNOWN"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-04-06T19:07:01.376095Z",
"id": "CVE-2026-34766",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-04-06T19:07:15.349Z"
}
}
]
}
}