Files
vuln-cve/data/2026/28xxx/CVE-2026-28745.json
T

206 lines
9.1 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-28745",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2026-04-08T19:28:49.467Z",
"datePublished": "2026-10-09T14:36:22.086Z",
"dateUpdated": "2026-10-11T17:05:28.832Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2026-10-09T14:36:22.086Z"
},
"title": "Red Lion Controls N-Tron 700 Series Storing Passwords in a Recoverable Format",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-257",
"description": "CWE-257",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Red Lion Controls",
"product": "700 Series",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "Firmware Versions 3.11.0",
"versionType": "custom"
},
{
"status": "affected",
"version": "0",
"lessThan": "Bootloader Versions 2.0.6.1",
"versionType": "custom"
},
{
"status": "unaffected",
"version": "3.11.1"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "Usernames and passwords, including the default credentials, are stored in the configuration file using weak encryption. If the default credentials are known by a malicious user, they could obtain other credentials on the system.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Usernames and passwords, including the default credentials, are stored in the configuration file using weak encryption. If the default credentials are known by a malicious user, they could obtain other credentials on the system."
}
]
}
],
"references": [
{
"url": "https://www.hms-networks.com/"
},
{
"url": "https://www.hms-networks.com/cybersecurity"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-281-01"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-281-01.json"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "UNCHANGED",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"availabilityImpact": "HIGH",
"baseSeverity": "HIGH",
"baseScore": 7.5,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "CRITICAL",
"baseScore": 9.3,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Red Lion controls recommends the following upgrades for the N-Tron 700 Series: \n\n\n * Upgrade to firmware version 3.11.1 or greater\n * Configure or disable the SNMP communities\n * Disable access to the web GUI\n\n\n\n\n\nThe upgrade procedure document can be viewed here https://www.hms-networks.com/ .\n\n\n\n\nThe advisory issued by HMS Networks regarding these vulnerabilities can be viewed here https://www.hms-networks.com/cybersecurity .",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<p>Red Lion controls recommends the following upgrades for the N-Tron 700 Series: <br></p><ul><li>Upgrade to firmware version 3.11.1 or greater</li><li>Configure or disable the SNMP communities</li><li>Disable access to the web GUI</li></ul>\n<p>The upgrade procedure document can be viewed <a href=\"https://www.hms-networks.com/\">here</a>.</p>\n<p>The advisory issued by HMS Networks regarding these vulnerabilities can be viewed <a href=\"https://www.hms-networks.com/cybersecurity\">here</a>.</p>"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Gabrianna (Ria) Milloway of Idaho National Laboratory reported this vulnerability to CISA.",
"type": "finder"
}
],
"source": {
"advisory": "ICSA-26-281-01",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2026-28745",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"version": "2.0.3",
"timestamp": "2026-10-11T16:49:55.930889Z"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-10-11T17:05:28.832Z"
}
}
]
}
}