Files
vuln-cve/data/2026/24xxx/CVE-2026-24433.json
T

176 lines
7.2 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-24433",
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"state": "PUBLISHED",
"assignerShortName": "VulnCheck",
"dateReserved": "2026-01-22T20:23:19.803Z",
"datePublished": "2026-01-26T17:40:59.149Z",
"dateUpdated": "2026-05-14T02:09:34.806Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "W30E V2",
"vendor": "Shenzhen Tenda Technology Co., Ltd.",
"versions": [
{
"lessThanOrEqual": "16.01.0.19(5037)",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:tenda:w30e_firmware:*:*:*:*:*:*:*:*",
"versionEndIncluding": "16.01.0.19(5037)"
}
]
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kazuma Matsumoto, a security researcher at GMO Cybersecurity by IERAE, Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users access the affected management pages."
}
],
"value": "Shenzhen Tenda W30E V2 firmware versions up to and including V16.01.0.19(5037) contain a stored cross-site scripting vulnerability in the user creation functionality. Insufficient input validation allows attacker-controlled script content to be stored and later executed when administrative users access the affected management pages."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "LOW",
"subIntegrityImpact": "LOW",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:P/VC:L/VI:L/VA:N/SC:L/SI:L/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck",
"dateUpdated": "2026-05-14T02:09:34.806Z"
},
"references": [
{
"tags": [
"product"
],
"url": "https://www.tendacn.com/product/W30E"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/tenda-w30e-v2-stored-xss-via-user-name-field"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Tenda W30E V2 Stored XSS via Username Field",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-01-26T21:08:14.818195Z",
"id": "CVE-2026-24433",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-01-26T21:08:23.838Z"
}
}
]
}
}