Files
vuln-cve/data/2026/23xxx/CVE-2026-23819.json
T

185 lines
7.5 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-23819",
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"state": "PUBLISHED",
"assignerShortName": "hpe",
"dateReserved": "2026-01-16T15:22:49.224Z",
"datePublished": "2026-05-12T18:31:33.726Z",
"dateUpdated": "2026-05-12T19:31:00.149Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe",
"dateUpdated": "2026-05-12T18:31:33.726Z"
},
"title": "Error in SSID Processing allows Stored XSS in Web Management Interface",
"affected": [
{
"vendor": "Hewlett Packard Enterprise (HPE)",
"product": "ArubaOS (AOS)",
"versions": [
{
"status": "affected",
"version": "10.8.0.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "10.7.0.0",
"lessThanOrEqual": "10.7.2.2",
"versionType": "semver"
},
{
"status": "affected",
"version": "10.4.0.0",
"lessThanOrEqual": "10.4.1.10",
"versionType": "semver"
},
{
"status": "affected",
"version": "8.13.0.0",
"lessThanOrEqual": "8.13.1.1",
"versionType": "semver"
},
{
"status": "affected",
"version": "8.12.0.0",
"lessThanOrEqual": "8.12.0.6",
"versionType": "semver"
},
{
"status": "affected",
"version": "8.10.0.0",
"lessThanOrEqual": "8.10.0.21",
"versionType": "semver"
}
],
"defaultStatus": "affected"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web-based management interface of Access Points running AOS-10 and AOS-8 Instant could allow an unauthenticated remote attacker to execute arbitrary JavaScript code in a victim's browser within the same local network. Successful exploitation could allow an attacker to compromise user data and potentially manipulate device configuration settings.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<p>A vulnerability in the web-based management interface of Access Points running AOS-10 and AOS-8 Instant could allow an unauthenticated remote attacker to execute arbitrary JavaScript code in a victim's browser within the same local network. Successful exploitation could allow an attacker to compromise user data and potentially manipulate device configuration settings.</p>"
}
]
}
],
"references": [
{
"url": "https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw05049en_us&docLocale=en_US"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "ADJACENT_NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "REQUIRED",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "HIGH",
"baseScore": 8.8,
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:H/I:H/A:H"
}
}
],
"credits": [
{
"lang": "en",
"value": "Michael Messner",
"type": "reporter"
},
{
"lang": "en",
"value": "Benedikt Kuehne",
"type": "reporter"
},
{
"lang": "en",
"value": "Caio Adler Goncalves Farias",
"type": "reporter"
},
{
"lang": "en",
"value": "Siemens Energy",
"type": "sponsor"
}
],
"source": {
"advisory": "HPESBNW05049",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"problemTypes": [
{
"descriptions": [
{
"type": "CWE",
"cweId": "CWE-79",
"lang": "en",
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-05-12T19:30:46.532539Z",
"id": "CVE-2026-23819",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-05-12T19:31:00.149Z"
}
}
]
}
}