"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-23197",
"assignerOrgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"state": "PUBLISHED",
"assignerShortName": "Linux",
"dateReserved": "2026-01-13T15:37:45.985Z",
"datePublished": "2026-02-14T16:27:22.919Z",
"dateUpdated": "2026-05-11T22:02:12.157Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"shortName": "Linux",
"dateUpdated": "2026-05-11T22:02:12.157Z"
},
"descriptions": [
{
"lang": "en",
"value": "In the Linux kernel, the following vulnerability has been resolved:\n\ni2c: imx: preserve error state in block data length handler\n\nWhen a block read returns an invalid length, zero or >I2C_SMBUS_BLOCK_MAX,\nthe length handler sets the state to IMX_I2C_STATE_FAILED. However,\ni2c_imx_master_isr() unconditionally overwrites this with\nIMX_I2C_STATE_READ_CONTINUE, causing an endless read loop that overruns\nbuffers and crashes the system.\n\nGuard the state transition to preserve error states set by the length\nhandler."
}
],
"affected": [
{
"product": "Linux",
"vendor": "Linux",
"defaultStatus": "unaffected",
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"programFiles": [
"drivers/i2c/busses/i2c-imx.c"
],
"versions": [
{
"version": "5f5c2d4579ca6836f5604cca979debd68ecfe23f",
"lessThan": "3f9b508b3eecc00a243edf320bd83834d6a9b482",
"status": "affected",
"versionType": "git"
},
{
"version": "5f5c2d4579ca6836f5604cca979debd68ecfe23f",
"lessThan": "b126097b0327437048bd045a0e4d273dea2910dd",
"status": "affected",
"versionType": "git"
}
]
},
{
"product": "Linux",
"vendor": "Linux",
"defaultStatus": "affected",
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"programFiles": [
"drivers/i2c/busses/i2c-imx.c"
],
"versions": [
{
"version": "6.13",
"status": "affected"
},
{
"version": "0",
"lessThan": "6.13",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.18.10",
"lessThanOrEqual": "6.18.*",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.19",
"lessThanOrEqual": "*",
"status": "unaffected",
"versionType": "original_commit_for_fix"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.13",
"versionEndExcluding": "6.18.10"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "6.13",
"versionEndExcluding": "6.19"
}
]
}
]
}
],
"references": [
{
"url": "https://git.kernel.org/stable/c/3f9b508b3eecc00a243edf320bd83834d6a9b482"
},
{
"url": "https://git.kernel.org/stable/c/b126097b0327437048bd045a0e4d273dea2910dd"
}
],
"title": "i2c: imx: preserve error state in block data length handler",
"x_generator": {
"engine": "bippy-1.2.0"
}
}
}
}