Files
vuln-cve/data/2026/22xxx/CVE-2026-22982.json
T

356 lines
16 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-22982",
"assignerOrgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"state": "PUBLISHED",
"assignerShortName": "Linux",
"dateReserved": "2026-01-13T15:37:45.936Z",
"datePublished": "2026-01-23T15:24:04.556Z",
"dateUpdated": "2026-11-10T12:41:06.874Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "416baaa9-dc9f-4396-8d5f-8c081fb06d67",
"shortName": "Linux",
"dateUpdated": "2026-05-11T21:57:42.765Z"
},
"descriptions": [
{
"lang": "en",
"value": "In the Linux kernel, the following vulnerability has been resolved:\n\nnet: mscc: ocelot: Fix crash when adding interface under a lag\n\nCommit 15faa1f67ab4 (\"lan966x: Fix crash when adding interface under a lag\")\nfixed a similar issue in the lan966x driver caused by a NULL pointer dereference.\nThe ocelot_set_aggr_pgids() function in the ocelot driver has similar logic\nand is susceptible to the same crash.\n\nThis issue specifically affects the ocelot_vsc7514.c frontend, which leaves\nunused ports as NULL pointers. The felix_vsc9959.c frontend is unaffected as\nit uses the DSA framework which registers all ports.\n\nFix this by checking if the port pointer is valid before accessing it."
}
],
"affected": [
{
"product": "Linux",
"vendor": "Linux",
"defaultStatus": "unaffected",
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"programFiles": [
"drivers/net/ethernet/mscc/ocelot.c"
],
"versions": [
{
"version": "528d3f190c98c8f7d9581f68db4af021696727b2",
"lessThan": "8767f238b0e6c3d0b295ac6dce9fbe6a99bd1b9d",
"status": "affected",
"versionType": "git"
},
{
"version": "528d3f190c98c8f7d9581f68db4af021696727b2",
"lessThan": "b17818307446c5a8d925a39a792261dbfa930041",
"status": "affected",
"versionType": "git"
},
{
"version": "528d3f190c98c8f7d9581f68db4af021696727b2",
"lessThan": "2985712dc76dfa670eb7fd607c09d4d48e5f5c6e",
"status": "affected",
"versionType": "git"
},
{
"version": "528d3f190c98c8f7d9581f68db4af021696727b2",
"lessThan": "03fb1708b7d1e76aecebf767ad059c319845039f",
"status": "affected",
"versionType": "git"
},
{
"version": "528d3f190c98c8f7d9581f68db4af021696727b2",
"lessThan": "f490af47bbee02441e356a1e0b86e3b3dd5120ff",
"status": "affected",
"versionType": "git"
},
{
"version": "528d3f190c98c8f7d9581f68db4af021696727b2",
"lessThan": "34f3ff52cb9fa7dbf04f5c734fcc4cb6ed5d1a95",
"status": "affected",
"versionType": "git"
}
]
},
{
"product": "Linux",
"vendor": "Linux",
"defaultStatus": "affected",
"repo": "https://git.kernel.org/pub/scm/linux/kernel/git/stable/linux.git",
"programFiles": [
"drivers/net/ethernet/mscc/ocelot.c"
],
"versions": [
{
"version": "5.12",
"status": "affected"
},
{
"version": "0",
"lessThan": "5.12",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "5.15.198",
"lessThanOrEqual": "5.15.*",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.1.161",
"lessThanOrEqual": "6.1.*",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.6.121",
"lessThanOrEqual": "6.6.*",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.12.66",
"lessThanOrEqual": "6.12.*",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.18.6",
"lessThanOrEqual": "6.18.*",
"status": "unaffected",
"versionType": "semver"
},
{
"version": "6.19",
"lessThanOrEqual": "*",
"status": "unaffected",
"versionType": "original_commit_for_fix"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.12",
"versionEndExcluding": "5.15.198"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.12",
"versionEndExcluding": "6.1.161"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.12",
"versionEndExcluding": "6.6.121"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.12",
"versionEndExcluding": "6.12.66"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.12",
"versionEndExcluding": "6.18.6"
},
{
"vulnerable": true,
"criteria": "cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:*",
"versionStartIncluding": "5.12",
"versionEndExcluding": "6.19"
}
]
}
]
}
],
"references": [
{
"url": "https://git.kernel.org/stable/c/8767f238b0e6c3d0b295ac6dce9fbe6a99bd1b9d"
},
{
"url": "https://git.kernel.org/stable/c/b17818307446c5a8d925a39a792261dbfa930041"
},
{
"url": "https://git.kernel.org/stable/c/2985712dc76dfa670eb7fd607c09d4d48e5f5c6e"
},
{
"url": "https://git.kernel.org/stable/c/03fb1708b7d1e76aecebf767ad059c319845039f"
},
{
"url": "https://git.kernel.org/stable/c/f490af47bbee02441e356a1e0b86e3b3dd5120ff"
},
{
"url": "https://git.kernel.org/stable/c/34f3ff52cb9fa7dbf04f5c734fcc4cb6ed5d1a95"
}
],
"title": "net: mscc: ocelot: Fix crash when adding interface under a lag",
"x_generator": {
"engine": "bippy-1.2.0"
}
},
"adp": [
{
"x_adpType": "supplier",
"providerMetadata": {
"orgId": "0b142b55-0307-4c5a-b3c9-f314f3fb7c5e",
"shortName": "siemens-SADP",
"dateUpdated": "2026-11-10T12:41:06.874Z"
},
"affected": [
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)",
"versions": [
{
"status": "affected",
"version": "V3.1.6",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)",
"versions": [
{
"status": "affected",
"version": "V3.1.7",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)",
"versions": [
{
"status": "affected",
"version": "V3.1.6",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AC0)",
"versions": [
{
"status": "affected",
"version": "V3.1.7",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)",
"versions": [
{
"status": "affected",
"version": "V3.1.6",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AB0)",
"versions": [
{
"status": "affected",
"version": "V3.1.7",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)",
"versions": [
{
"status": "affected",
"version": "V3.1.6",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIMATIC S7-1500 CPU 1518F-4 PN/DP MFP (6ES7518-4FX00-1AC0)",
"versions": [
{
"status": "affected",
"version": "V3.1.7",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)",
"versions": [
{
"status": "affected",
"version": "V3.1.6",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "SIPLUS S7-1500 CPU 1518-4 PN/DP MFP (6AG1518-4AX00-4AC0)",
"versions": [
{
"status": "affected",
"version": "V3.1.7",
"lessThan": "*",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-019113.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457936.html"
}
]
}
]
}
}