Files
vuln-cve/data/2026/19xxx/CVE-2026-19188.json
T

195 lines
8.6 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-19188",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2026-08-06T19:51:14.688Z",
"datePublished": "2026-08-14T18:20:48.691Z",
"dateUpdated": "2026-08-14T18:52:46.447Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2026-08-14T18:21:52.712Z"
},
"title": "Haiwell IoT Cloud HMI Gateway OS Command Injection",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-78",
"description": "CWE-78",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Haiwell",
"product": "Haiwell IoT Cloud HMI Gateway",
"versions": [
{
"status": "affected",
"version": "3.40.1.12"
},
{
"status": "unaffected",
"version": "3.50.1.19"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "A critical OS command injection vulnerability has been identified in the\n Haiwell IoT Cloud HMI Gateway product. The vulnerability exists in the \nNet Check feature accessible via the /setting endpoint. The cmdPing \nSocket.io event fails to properly sanitize user-supplied input before \npassing it to the underlying operating system, allowing an attacker to \ninject and execute arbitrary OS commands with root privileges.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "A critical OS command injection vulnerability has been identified in the\n Haiwell IoT Cloud HMI Gateway product. The vulnerability exists in the \nNet Check feature accessible via the /setting endpoint. The cmdPing \nSocket.io event fails to properly sanitize user-supplied input before \npassing it to the underlying operating system, allowing an attacker to \ninject and execute arbitrary OS commands with root privileges."
}
]
}
],
"references": [
{
"url": "https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361"
},
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-225-02"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2026/icsa-26-225-02.json"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV3_1": {
"version": "3.1",
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"scope": "CHANGED",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"availabilityImpact": "HIGH",
"baseSeverity": "CRITICAL",
"baseScore": 10,
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H"
}
},
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"vulnAvailabilityImpact": "HIGH",
"subAvailabilityImpact": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "CRITICAL",
"baseScore": 10,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Haiwell has addressed the issue in patch version number \nScada-v3.50.1.19, which is available for download on their website: \n https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Haiwell has addressed the issue in patch version number \nScada-v3.50.1.19, which is available for download on their website:&nbsp;<br><a href=\"https://en.haiwell.com/app/system/entrance.php?m=include&amp;c=access&amp;a=dodown&amp;lang=en&amp;id=361\">https://en.haiwell.com/app/system/entrance.php?m=include&amp;c=access&amp;a=dodown&amp;lang=en&amp;id=361</a>"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Fiqram Akmal reported this vulnerability to CISA.",
"type": "finder"
}
],
"source": {
"advisory": "ICSA-26-225-02",
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-08-14T18:52:34.918884Z",
"id": "CVE-2026-19188",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-08-14T18:52:46.447Z"
}
}
]
}
}