152 lines
8.2 KiB
JSON
152 lines
8.2 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2026-17494",
|
|
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "ibm",
|
|
"dateReserved": "2026-07-26T00:32:10.239Z",
|
|
"datePublished": "2026-08-19T18:42:02.286Z",
|
|
"dateUpdated": "2026-08-22T03:56:09.352Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
|
|
"shortName": "ibm",
|
|
"dateUpdated": "2026-08-19T19:00:19.451Z"
|
|
},
|
|
"title": "Power System Buffer Overflow",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-121",
|
|
"description": "CWE-121 Stack-based Buffer Overflow",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "IBM",
|
|
"product": "Power Systems Firmware",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "FW1120.00"
|
|
},
|
|
{
|
|
"status": "affected",
|
|
"version": "FW1110.00",
|
|
"lessThanOrEqual": "FW1110.30",
|
|
"versionType": "semver"
|
|
}
|
|
],
|
|
"cpes": [
|
|
"cpe:2.3:o:ibm:power_systems_firmware:fw1120.00:*:*:*:*:*:*:*",
|
|
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.00:*:*:*:*:*:*:*",
|
|
"cpe:2.3:o:ibm:power_systems_firmware:fw1110.30:*:*:*:*:*:*:*"
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "IBM Power Systems Firmware FW1120.00, and FW1110.00 through FW1110.30 is affected by a vulnerability in the interface between the BMC and the host system. An attacker with service access to the BMC can send a specially crafted command, allowing arbitrary code to be executed on the host system, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "<p>IBM Power Systems Firmware FW1120.00, and FW1110.00 through FW1110.30 is affected by a vulnerability in the interface between the BMC and the host system. An attacker with service access to the BMC can send a specially crafted command, allowing arbitrary code to be executed on the host system, giving full control over the host system and all hosted partitions, resulting in a confidentiality, integrity, and availability impact.</p>"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.ibm.com/support/pages/node/7283220",
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"patch"
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"attackVector": "LOCAL",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "HIGH",
|
|
"userInteraction": "NONE",
|
|
"scope": "CHANGED",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"availabilityImpact": "HIGH",
|
|
"baseSeverity": "HIGH",
|
|
"baseScore": 8.2,
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H"
|
|
}
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System E1180 (9080-HEU)\n\n\nCustomers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.\nPower 11\n\n * IBM Power System S1122 (9824-22A)\n * IBM Power System S1124 (9824-42A)\n * IBM Power System S1122s (9824-22B)\n * IBM Power System S1114 (9824-41B)\n * IBM Power System L1122 (9856-22H)\n * IBM Power System L1124 (9856-42H)\n * IBM Power System E1150 (9043-MRU)\n\n\nCustomers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.\n\n\n\nPower 11\n\n * IBM Power System S1112 (9242-21B, 9242-21T)\n\n\nThe images mentioned above can be located at IBM Fix Central : https://www.ibm.com/support/fixcentral/ https://www.ibm.com/support/fixcentral/",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "<p>Customers with the products below should install FW1110.31(1110_134), FW1120.01(1120_167), or newer to remediate this vulnerability.<br/>Power 11</p><ol><li>IBM Power System E1180 (9080-HEU)</li></ol><p>Customers with the products below should install FW1110.31(1110_155), FW1120.01(1120_190), or newer to remediate this vulnerability.<br/>Power 11</p><ol><li>IBM Power System S1122 (9824-22A)</li><li>IBM Power System S1124 (9824-42A)</li><li>IBM Power System S1122s (9824-22B)</li><li>IBM Power System S1114 (9824-41B)</li><li>IBM Power System L1122 (9856-22H)</li><li>IBM Power System L1124 (9856-42H)</li><li>IBM Power System E1150 (9043-MRU)</li></ol><p>Customers with the products below should install FW1120.01(1120_190), or newer to remediate this vulnerability.</p><p>Power 11</p><ol><li>IBM Power System S1112 (9242-21B, 9242-21T)</li></ol><p><em>The images mentioned above can be located at IBM Fix Central : </em><a href=\"https://www.ibm.com/support/fixcentral/\" rel=\"noopener noreferrer nofollow\"><em>https://www.ibm.com/support/fixcentral/</em></a></p>"
|
|
}
|
|
]
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-08-21T00:00:00+00:00",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3",
|
|
"id": "CVE-2026-17494"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-08-22T03:56:09.352Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |