194 lines
8.5 KiB
JSON
194 lines
8.5 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2026-15570",
|
|
"assignerOrgId": "5431be70-064b-4f6a-be51-69eacabef109",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "Vestel",
|
|
"dateReserved": "2026-07-13T07:02:12.638Z",
|
|
"datePublished": "2026-08-07T13:32:45.790Z",
|
|
"dateUpdated": "2026-08-07T14:26:15.788Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "5431be70-064b-4f6a-be51-69eacabef109",
|
|
"shortName": "Vestel",
|
|
"dateUpdated": "2026-08-07T13:32:45.790Z"
|
|
},
|
|
"title": "Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command",
|
|
"datePublic": "2026-08-07T13:13:00.000Z",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-918",
|
|
"description": "CWE-918 Server-Side request forgery (SSRF)",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"impacts": [
|
|
{
|
|
"capecId": "CAPEC-664",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "CAPEC-664 Server Side Request Forgery"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Vestel",
|
|
"product": "Telefunken TE24553B45V2DZ Smart TV",
|
|
"platforms": [
|
|
"Vestel MB181 / Voltron181 / TiVo OS"
|
|
],
|
|
"modules": [
|
|
"Smart Center",
|
|
"browserseturl command"
|
|
],
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "V2.78.0.0"
|
|
},
|
|
{
|
|
"status": "unaffected",
|
|
"version": "V2.85.2.0"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0."
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media&token=61fb45d3-b88e-4810-a620-693a1c693db4",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
]
|
|
},
|
|
{
|
|
"url": "https://vestelinternational.com/security-advisories",
|
|
"tags": [
|
|
"vendor-advisory"
|
|
]
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV4_0": {
|
|
"attackVector": "ADJACENT",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "NONE",
|
|
"subConfidentialityImpact": "NONE",
|
|
"vulnIntegrityImpact": "HIGH",
|
|
"subIntegrityImpact": "NONE",
|
|
"vulnAvailabilityImpact": "LOW",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"version": "4.0",
|
|
"baseSeverity": "HIGH",
|
|
"baseScore": 7.1,
|
|
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N"
|
|
}
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Upgrade the affected product to firmware version V2.85.2.0.",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "Upgrade the affected product to firmware version V2.85.2.0."
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Francesco Caligiuri",
|
|
"type": "finder"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "VSA-4",
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"x_generator": {
|
|
"engine": "Vulnogram 1.0.4"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-08-07T14:25:53.841501Z",
|
|
"id": "CVE-2026-15570",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-08-07T14:26:15.788Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |