Files
vuln-cve/data/2026/15xxx/CVE-2026-15570.json
T

194 lines
8.5 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-15570",
"assignerOrgId": "5431be70-064b-4f6a-be51-69eacabef109",
"state": "PUBLISHED",
"assignerShortName": "Vestel",
"dateReserved": "2026-07-13T07:02:12.638Z",
"datePublished": "2026-08-07T13:32:45.790Z",
"dateUpdated": "2026-08-07T14:26:15.788Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "5431be70-064b-4f6a-be51-69eacabef109",
"shortName": "Vestel",
"dateUpdated": "2026-08-07T13:32:45.790Z"
},
"title": "Improper URL Scheme and Destination Validation in SmartCenter browserseturl Command",
"datePublic": "2026-08-07T13:13:00.000Z",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-918",
"description": "CWE-918 Server-Side request forgery (SSRF)",
"type": "CWE"
}
]
}
],
"impacts": [
{
"capecId": "CAPEC-664",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-664 Server Side Request Forgery"
}
]
}
],
"affected": [
{
"vendor": "Vestel",
"product": "Telefunken TE24553B45V2DZ Smart TV",
"platforms": [
"Vestel MB181 / Voltron181 / TiVo OS"
],
"modules": [
"Smart Center",
"browserseturl command"
],
"versions": [
{
"status": "affected",
"version": "V2.78.0.0"
},
{
"status": "unaffected",
"version": "V2.85.2.0"
}
],
"defaultStatus": "unknown"
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "An improper restriction of URL schemes and destinations in the SmartCenter browserseturl command in the Telefunken TE24553B45V2DZ Smart TV running on the Vestel MB181 / Voltron181 / TiVo OS platform allows an attacker with access to the same local network to cause the embedded browser to issue requests to unintended loopback/internal destinations, including 127.0.0.1 addresses. In demonstrated scenarios, requests initiated through the SmartCenter browserseturl mechanism could reach an internal service and receive a successful response, although the same destination was not reachable through normal browser navigation. The issue affects firmware version V2.78.0.0 and is fixed in firmware version V2.85.2.0."
}
]
}
],
"references": [
{
"url": "https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F4%2FVSA-4.pdf?alt=media&token=61fb45d3-b88e-4810-a620-693a1c693db4",
"tags": [
"vendor-advisory"
]
},
{
"url": "https://vestelinternational.com/security-advisories",
"tags": [
"vendor-advisory"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "ADJACENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "HIGH",
"baseScore": 7.1,
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:L/SC:N/SI:N/SA:N"
}
}
],
"solutions": [
{
"lang": "en",
"value": "Upgrade the affected product to firmware version V2.85.2.0.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "Upgrade the affected product to firmware version V2.85.2.0."
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Francesco Caligiuri",
"type": "finder"
}
],
"source": {
"advisory": "VSA-4",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-08-07T14:25:53.841501Z",
"id": "CVE-2026-15570",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-08-07T14:26:15.788Z"
}
}
]
}
}