Files
vuln-cve/data/2026/12xxx/CVE-2026-12661.json
T

159 lines
6.5 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2026-12661",
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"state": "PUBLISHED",
"assignerShortName": "Rockwell",
"dateReserved": "2026-06-18T18:59:07.379Z",
"datePublished": "2026-09-01T13:41:53.240Z",
"dateUpdated": "2026-09-02T12:52:36.085Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell",
"dateUpdated": "2026-09-02T12:52:36.085Z"
},
"title": "FactoryTalk® Historian Machine Edition - Out-of-Bounds Write Vulnerability",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-121",
"description": "CWE-121 Stack-based buffer overflow",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "Rockwell Automation",
"product": "FactoryTalk® Historian Machine Edition",
"versions": [
{
"status": "affected",
"version": "Series C: 7.101 Series B: 5.202"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:rockwell_automation:factorytalk_historian_machine_edition:series_c_7.101_series_b_5.202:*:*:*:*:*:*:*"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A denial-of-service security issue exists within FactoryTalk® Historian Machine Edition.  A network adjacent attacker who is authenticated could send crafted requests to the web interface, resulting in buffer overflow conditions that may cause the device to crash and become unresponsive.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "A denial-of-service security issue exists within FactoryTalk® Historian Machine Edition.  A network adjacent attacker who is authenticated could send crafted requests to the web interface, resulting in buffer overflow conditions that may cause the device to crash and become unresponsive. "
}
]
}
],
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1796.html"
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "ADJACENT",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "HIGH",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "MEDIUM",
"baseScore": 4.8,
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N"
}
}
],
"source": {
"advisory": "SD1796",
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.5"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-09-01T15:48:47.860540Z",
"id": "CVE-2026-12661",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-09-01T15:49:18.327Z"
}
}
]
}
}