Files
vuln-cve/data/2025/9xxx/CVE-2025-9065.json
T

141 lines
5.8 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-9065",
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"state": "PUBLISHED",
"assignerShortName": "Rockwell",
"dateReserved": "2025-08-15T13:58:23.749Z",
"datePublished": "2025-09-09T12:51:42.091Z",
"dateUpdated": "2025-09-09T13:23:24.291Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ThinManager",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "13.0 - 14.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<span style=\"background-color: rgb(255, 255, 255);\">A server-side request forgery security issue exists within Rockwell Automation ThinManager® software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer® service account NTLM hash.</span>"
}
],
"value": "A server-side request forgery security issue exists within Rockwell Automation ThinManager® software due to the lack of input sanitization. Authenticated attackers can exploit this vulnerability by specifying external SMB paths, exposing the ThinServer® service account NTLM hash."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-610",
"description": "CWE-610: Externally Controlled Reference to a Resource in Another Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell",
"dateUpdated": "2025-09-09T12:51:42.091Z"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1743.html"
}
],
"source": {
"advisory": "SD1743",
"discovery": "INTERNAL"
},
"title": "Rockwell Automation ThinManager® Server-Side Request Forgery Vulnerability",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-09-09T13:23:19.121711Z",
"id": "CVE-2025-9065",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-09-09T13:23:24.291Z"
}
}
]
}
}