212 lines
9.2 KiB
JSON
212 lines
9.2 KiB
JSON
{
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.2",
|
||
"cveMetadata": {
|
||
"cveId": "CVE-2025-69425",
|
||
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
|
||
"state": "PUBLISHED",
|
||
"assignerShortName": "VulnCheck",
|
||
"dateReserved": "2026-01-08T20:48:39.252Z",
|
||
"datePublished": "2026-01-09T16:14:32.065Z",
|
||
"dateUpdated": "2026-07-28T01:48:12.889Z"
|
||
},
|
||
"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "vRIoT IoT Controller",
|
||
"vendor": "RUCKUS Networks",
|
||
"versions": [
|
||
{
|
||
"lessThan": "3.0.0.0 (GA)",
|
||
"status": "affected",
|
||
"version": "2.3.0.0 (GA)",
|
||
"versionType": "custom"
|
||
},
|
||
{
|
||
"lessThan": "3.0.0.0 (GA)",
|
||
"status": "affected",
|
||
"version": "2.3.1.0 (MR)",
|
||
"versionType": "custom"
|
||
},
|
||
{
|
||
"lessThan": "3.0.0.0 (GA)",
|
||
"status": "affected",
|
||
"version": "2.4.0.0 (GA)",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"cpeApplicability": [
|
||
{
|
||
"nodes": [
|
||
{
|
||
"operator": "OR",
|
||
"negate": false,
|
||
"cpeMatch": [
|
||
{
|
||
"vulnerable": true,
|
||
"criteria": "cpe:2.3:a:aviatrix:controller:*:*:*:*:*:*:*:*",
|
||
"versionStartIncluding": "2.3.0.0",
|
||
"versionEndExcluding": "3.0.0.0"
|
||
},
|
||
{
|
||
"vulnerable": true,
|
||
"criteria": "cpe:2.3:a:aviatrix:controller:*:*:*:*:*:*:*:*",
|
||
"versionStartIncluding": "2.3.1.0",
|
||
"versionEndExcluding": "3.0.0.0"
|
||
},
|
||
{
|
||
"vulnerable": true,
|
||
"criteria": "cpe:2.3:a:aviatrix:controller:*:*:*:*:*:*:*:*",
|
||
"versionStartIncluding": "2.4.0.0",
|
||
"versionEndExcluding": "3.0.0.0"
|
||
}
|
||
]
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"type": "finder",
|
||
"value": "Ivan Racic"
|
||
}
|
||
],
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "The Ruckus vRIoT <span style=\"background-color: rgb(255, 255, 255);\">IoT Controller</span> firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise."
|
||
}
|
||
],
|
||
"value": "The Ruckus vRIoT IoT Controller firmware versions prior to 3.0.0.0 (GA) expose a command execution service on TCP port 2004 running with root privileges. Authentication to this service relies on a hardcoded Time-based One-Time Password (TOTP) secret and an embedded static token. An attacker who extracts these credentials from the appliance or a compromised device can generate valid authentication tokens and execute arbitrary OS commands with root privileges, resulting in complete system compromise."
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV4_0": {
|
||
"Automatable": "NOT_DEFINED",
|
||
"Recovery": "NOT_DEFINED",
|
||
"Safety": "NOT_DEFINED",
|
||
"attackComplexity": "LOW",
|
||
"attackRequirements": "NONE",
|
||
"attackVector": "NETWORK",
|
||
"baseScore": 10,
|
||
"baseSeverity": "CRITICAL",
|
||
"exploitMaturity": "NOT_DEFINED",
|
||
"privilegesRequired": "NONE",
|
||
"providerUrgency": "NOT_DEFINED",
|
||
"subAvailabilityImpact": "HIGH",
|
||
"subConfidentialityImpact": "HIGH",
|
||
"subIntegrityImpact": "HIGH",
|
||
"userInteraction": "NONE",
|
||
"valueDensity": "NOT_DEFINED",
|
||
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
|
||
"version": "4.0",
|
||
"vulnAvailabilityImpact": "HIGH",
|
||
"vulnConfidentialityImpact": "HIGH",
|
||
"vulnIntegrityImpact": "HIGH",
|
||
"vulnerabilityResponseEffort": "NOT_DEFINED"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-306",
|
||
"description": "CWE-306 Missing Authentication for Critical Function",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-798",
|
||
"description": "CWE-798 Use of Hard-coded Credentials",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
|
||
"shortName": "VulnCheck",
|
||
"dateUpdated": "2026-07-28T01:48:12.889Z"
|
||
},
|
||
"references": [
|
||
{
|
||
"tags": [
|
||
"vendor-advisory",
|
||
"patch"
|
||
],
|
||
"url": "https://support.ruckuswireless.com/security_bulletins/336"
|
||
},
|
||
{
|
||
"tags": [
|
||
"third-party-advisory"
|
||
],
|
||
"url": "https://www.vulncheck.com/advisories/ruckus-vriot-iot-controller-hardcoded-tokens-rce"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "UNKNOWN"
|
||
},
|
||
"title": "Ruckus vRIoT IoT Controller < 3.0.0.0 Hardcoded Tokens RCE",
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.5.0"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"timestamp": "2026-01-09T17:48:39.859822Z",
|
||
"id": "CVE-2025-69425",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "yes"
|
||
},
|
||
{
|
||
"Technical Impact": "total"
|
||
}
|
||
],
|
||
"role": "CISA Coordinator",
|
||
"version": "2.0.3"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2026-01-09T18:37:55.088Z"
|
||
}
|
||
}
|
||
]
|
||
}
|
||
} |