"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-59780",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2025-11-06T20:44:49.360Z",
"datePublished": "2025-11-14T23:26:35.691Z",
"dateUpdated": "2025-11-17T16:54:08.683Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Lynx+ Gateway",
"vendor": "General Industrial Controls",
"versions": [
{
"status": "affected",
"version": "Version R08"
},
{
"status": "affected",
"version": "Version V03"
},
{
"status": "affected",
"version": "Version V05"
},
{
"status": "affected",
"version": "Version V18"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Abhishek Pandey from Payatu Security Consulting Pvt. Ltd. reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
}
],
"value": "General Industrial Controls Lynx+ Gateway is missing critical authentication in the embedded web server which \ncould allow an attacker to send GET requests to obtain sensitive device \ninformation."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2025-11-14T23:26:35.691Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-317-08"
},
{
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-317-08.json"
}
],
"source": {
"advisory": "ICSA-25-317-08",
"discovery": "EXTERNAL"
},
"title": "General Industrial Controls Lynx+ Gateway Missing Authentication for Critical Function",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "General Industrial Controls (GIC) did not respond to CISA's attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to <a target=\"_blank\" rel=\"nofollow\">GIC</a> for more information.\n\n<br>"
}
],
"value": "General Industrial Controls (GIC) did not respond to CISA's attempts to \ncoordinate. Users of General Industrial Controls Lynx+ Gateway are \nencouraged to reach out to GIC for more information."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-11-17T16:53:36.856914Z",
"id": "CVE-2025-59780",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-11-17T16:54:08.683Z"
}
}
]
}
}