Files
vuln-cve/data/2025/58xxx/CVE-2025-58405.json
T

151 lines
6.3 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-58405",
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"state": "PUBLISHED",
"assignerShortName": "CERT-PL",
"dateReserved": "2025-09-01T07:18:45.944Z",
"datePublished": "2026-03-02T11:16:45.223Z",
"dateUpdated": "2026-03-02T12:27:59.659Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CGM CLININET",
"vendor": "CGM",
"versions": [
{
"lessThan": "2025.MS3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses."
}
],
"value": "The CGM CLININET application does not implement any mechanisms that prevent clickjacking attacks, neither HTTP security headers nor HTML-based frame‑busting protections were detected. As a result, an attacker can embed the application inside a maliciously crafted IFRAME and trick users into performing unintended actions, including potentially bypassing CSRF/XSRF defenses."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1021",
"description": "CWE-1021 Improper Restriction of Rendered UI Layers or Frames",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL",
"dateUpdated": "2026-03-02T11:16:45.223Z"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/en/posts/2026/03/CVE-2025-10350/"
},
{
"tags": [
"product"
],
"url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Lack of protection mechanisms against Clickjacking attacks",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-03-02T12:24:46.564303Z",
"id": "CVE-2025-58405",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-03-02T12:27:59.659Z"
}
}
]
}
}