Files
vuln-cve/data/2025/54xxx/CVE-2025-54926.json
T

157 lines
6.3 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-54926",
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"state": "PUBLISHED",
"assignerShortName": "schneider",
"dateReserved": "2025-08-01T04:38:47.036Z",
"datePublished": "2025-08-20T13:48:02.393Z",
"dateUpdated": "2025-08-20T17:21:50.700Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure™ Power Monitoring Expert (PME)",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022"
},
{
"status": "affected",
"version": "Version 2023"
},
{
"status": "affected",
"version": "Version 2024"
},
{
"status": "affected",
"version": "Version 2024 R2"
}
]
},
{
"defaultStatus": "unaffected",
"product": "EcoStruxure™ Power Operation (EPO) Advanced Reporting and Dashboards Module",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "Version 2022 w/ Advanced Reporting Module"
},
{
"status": "affected",
"version": "Version 2024 w/ Advanced Reporting Module"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed."
}
],
"value": "CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that could cause remote code execution when an authenticated attacker with admin privileges uploads a malicious file over HTTP which then gets executed."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider",
"dateUpdated": "2025-08-20T13:48:02.393Z"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-224-02&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-224-02.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-08-20T17:21:43.158876Z",
"id": "CVE-2025-54926",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-08-20T17:21:50.700Z"
}
}
]
}
}