189 lines
8.0 KiB
JSON
189 lines
8.0 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2025-52459",
|
|
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "icscert",
|
|
"dateReserved": "2025-07-02T15:12:58.643Z",
|
|
"datePublished": "2025-07-10T23:28:08.679Z",
|
|
"dateUpdated": "2025-07-11T13:29:56.285Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "iView",
|
|
"vendor": "Advantech",
|
|
"versions": [
|
|
{
|
|
"lessThan": "5.7.05 build 7057",
|
|
"status": "affected",
|
|
"version": "0",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"type": "finder",
|
|
"value": "Alex Williams of Converge Technology Solutions reported these vulnerabilities to CISA."
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "A vulnerability exists in Advantech iView that allows for argument \ninjection in NetworkServlet.backupDatabase(). This issue requires an \nauthenticated attacker with at least user-level privileges. Certain \nparameters can be used directly in a command without proper \nsanitization, allowing arbitrary arguments to be injected. This can \nresult in information disclosure, including sensitive database \ncredentials."
|
|
}
|
|
],
|
|
"value": "A vulnerability exists in Advantech iView that allows for argument \ninjection in NetworkServlet.backupDatabase(). This issue requires an \nauthenticated attacker with at least user-level privileges. Certain \nparameters can be used directly in a command without proper \nsanitization, allowing arbitrary arguments to be injected. This can \nresult in information disclosure, including sensitive database \ncredentials."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 6.5,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"cvssV4_0": {
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"attackVector": "NETWORK",
|
|
"baseScore": 7.1,
|
|
"baseSeverity": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"subAvailabilityImpact": "NONE",
|
|
"subConfidentialityImpact": "NONE",
|
|
"subIntegrityImpact": "NONE",
|
|
"userInteraction": "NONE",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
|
|
"version": "4.0",
|
|
"vulnAvailabilityImpact": "NONE",
|
|
"vulnConfidentialityImpact": "HIGH",
|
|
"vulnIntegrityImpact": "NONE",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-88",
|
|
"description": "CWE-88",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"shortName": "icscert",
|
|
"dateUpdated": "2025-07-10T23:28:08.679Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-191-08"
|
|
},
|
|
{
|
|
"url": "https://www.advantech.com/en/support/details/firmware-?id=1-HIPU-183"
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Advantech recommends users update to <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.advantech.com/en/support/details/firmware-?id=1-HIPU-183\">v5.7.05 build 7057</a>.\n\n<br>"
|
|
}
|
|
],
|
|
"value": "Advantech recommends users update to v5.7.05 build 7057 https://www.advantech.com/en/support/details/firmware- ."
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-25-191-08",
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"title": "Advantech iView Argument Injection",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-07-11T13:29:50.282666Z",
|
|
"id": "CVE-2025-52459",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-07-11T13:29:56.285Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |