Files
vuln-cve/data/2025/40xxx/CVE-2025-40945.json
T

307 lines
12 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-40945",
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"state": "PUBLISHED",
"assignerShortName": "siemens",
"dateReserved": "2025-04-16T09:06:15.879Z",
"datePublished": "2026-07-14T09:19:08.857Z",
"dateUpdated": "2026-07-14T12:16:59.871Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2026-07-14T09:19:08.857Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in COMOS V10.4.5 (All versions < V10.4.5.0.2), COMOS V10.6 (All versions < V10.6.1), Designcenter NX (All versions < V2512.7000), Simcenter 3D (All versions < V2512.7000), Simcenter Femap V2506 (All versions < V2506.0003), Simcenter Femap V2512 (All versions < V2512.0002), Simcenter Nastran (All versions < V2606), Simcenter STAR-CCM+ (All versions < V2606), Solid Edge SE2025 (All versions < V225.0 Update 13), Solid Edge SE2026 (All versions < V226.0 Update 04), Teamcenter Visualization V2412 (All versions < V2412.0012), Teamcenter Visualization V2506 (All versions < V2506.0009), Teamcenter Visualization V2512 (All versions < V2512.2605), Tecnomatix Plant Simulation V2404 (All versions < V2404.0022), Tecnomatix Plant Simulation V2504 (All versions < V2504.0010), Tecnomatix Process Simulate (All versions < V2606). Untrusted search path in IAM Client SDK may allow an authenticated user to potentially enable escalation of privilege via local access."
}
],
"affected": [
{
"vendor": "Siemens",
"product": "COMOS V10.4.5",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V10.4.5.0.2",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "COMOS V10.6",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V10.6.1",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Designcenter NX",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2512.7000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Simcenter 3D",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2512.7000",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Simcenter Femap V2506",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2506.0003",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Simcenter Femap V2512",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2512.0002",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Simcenter Nastran",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2606",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Simcenter STAR-CCM+",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2606",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2025",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V225.0 Update 13",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Solid Edge SE2026",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V226.0 Update 04",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2412",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2412.0012",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2506",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2506.0009",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Teamcenter Visualization V2512",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2512.2605",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2404",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2404.0022",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Plant Simulation V2504",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2504.0010",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "Tecnomatix Process Simulate",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2606",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 6.7,
"baseSeverity": "MEDIUM"
}
},
{
"cvssV4_0": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"baseScore": 8.5,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-426",
"description": "CWE-426: Untrusted Search Path",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-288252.html"
}
]
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-07-14T12:16:50.783446Z",
"id": "CVE-2025-40945",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-07-14T12:16:59.871Z"
}
}
]
}
}