"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2025-3606",
|
|
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "icscert",
|
|
"dateReserved": "2025-04-14T19:44:14.176Z",
|
|
"datePublished": "2025-04-24T23:15:52.975Z",
|
|
"dateUpdated": "2025-04-25T16:02:38.056Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "AC Charger EVC04",
|
|
"vendor": "Vestel",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "3.75.0"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"type": "finder",
|
|
"value": "Cumhur Kizilari reported this vulnerability to CISA."
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Vestel AC Charger \nversion \n\n3.75.0 contains a vulnerability that \ncould enable an attacker to access files containing sensitive \ninformation, such as credentials which could be used to further \ncompromise the device."
|
|
}
|
|
],
|
|
"value": "Vestel AC Charger \nversion \n\n3.75.0 contains a vulnerability that \ncould enable an attacker to access files containing sensitive \ninformation, such as credentials which could be used to further \ncompromise the device."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"cvssV4_0": {
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"attackVector": "NETWORK",
|
|
"baseScore": 8.7,
|
|
"baseSeverity": "HIGH",
|
|
"privilegesRequired": "NONE",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"subAvailabilityImpact": "NONE",
|
|
"subConfidentialityImpact": "NONE",
|
|
"subIntegrityImpact": "NONE",
|
|
"userInteraction": "NONE",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
|
|
"version": "4.0",
|
|
"vulnAvailabilityImpact": "NONE",
|
|
"vulnConfidentialityImpact": "HIGH",
|
|
"vulnIntegrityImpact": "NONE",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-497",
|
|
"description": "CWE-497",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"shortName": "icscert",
|
|
"dateUpdated": "2025-04-24T23:15:52.975Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-114-03"
|
|
},
|
|
{
|
|
"url": "https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf?alt=media&token=8201f299-5014-4720-9200-f1b335736ac1"
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Vestel strongly suggests that users of the related AC chargers update to version V3.187 or a higher version.<br>"
|
|
}
|
|
],
|
|
"value": "Vestel strongly suggests that users of the related AC chargers update to version V3.187 or a higher version."
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-25-114-03",
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"title": "Vestel AC Charger Exposure of Sensitive System Information to an Unauthorized Control Sphere",
|
|
"workarounds": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "<p>Avoid using open network:</p>\n<ul>\n<li>Use secure methods like virtual private networks (VPNs) for remote \naccess. Regularly update VPNs to their latest versions and ensure that \nconnected devices maintain strong security measures.</li>\n<li>Reduce network exposure for applications and endpoints. Only make \nthem accessible via the Internet if specifically designed for and \nrequired by their intended use.</li>\n</ul>\n<p>Login Credentials Management:</p>\n<ul>\n<li>Force end user to revise the factory default set username and password of webconfig page.</li>\n<li>Remove any printed documents such as installation guide, instruction\n book, quick start guide from web where login credentials are featured.</li>\n</ul>\n<p>Please refer to Vestel's <a target=\"_blank\" rel=\"nofollow\" href=\"https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf?alt=media&token=8201f299-5014-4720-9200-f1b335736ac1\">advisory</a> for more information.\n\n<br></p>"
|
|
}
|
|
],
|
|
"value": "Avoid using open network:\n\n\n\n * Use secure methods like virtual private networks (VPNs) for remote \naccess. Regularly update VPNs to their latest versions and ensure that \nconnected devices maintain strong security measures.\n\n * Reduce network exposure for applications and endpoints. Only make \nthem accessible via the Internet if specifically designed for and \nrequired by their intended use.\n\n\n\n\nLogin Credentials Management:\n\n\n\n * Force end user to revise the factory default set username and password of webconfig page.\n\n * Remove any printed documents such as installation guide, instruction\n book, quick start guide from web where login credentials are featured.\n\n\n\n\nPlease refer to Vestel's advisory https://firebasestorage.googleapis.com/v0/b/vestel-shield.firebasestorage.app/o/PRODUCTION%2F1%2FVSA-1_R2.pdf for more information."
|
|
}
|
|
],
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-04-25T15:37:27.258163Z",
|
|
"id": "CVE-2025-3606",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "yes"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-04-25T16:02:38.056Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |