438 lines
16 KiB
JSON
438 lines
16 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2025-3020",
|
|
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "CERTVDE",
|
|
"dateReserved": "2025-03-31T06:31:36.670Z",
|
|
"datePublished": "2025-05-06T08:01:58.965Z",
|
|
"dateUpdated": "2025-05-06T13:52:19.548Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "ERP-Gateway 12x Digital Input, 6x Digital Relais",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "ERP-Gateway 2x Digital Input, 2x Digital Output",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "ERP-Gateway 2x Digital PoE",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Alarm 6x6 DigitalWeb-Alarm 6x6 Digital",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Count 6x Digital",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"lessThan": "3.79",
|
|
"status": "affected",
|
|
"version": "0",
|
|
"versionType": "semver"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Graph Air Quality",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO 12x Digital Input, 6x Digital Relais",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO 12x Digital Input, 6x Digital Relais",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO 12x Digital Input, 6x Digital Relais",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Analog-In/Out 2x 0/4..20mA PoE",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 12xIn, 12xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 12xIn, 12xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 12xIn, 12xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"lessThan": "4.08",
|
|
"status": "affected",
|
|
"version": "0",
|
|
"versionType": "semver"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 12xIn, 12xOut, 1xRS232",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 12xIn, 12xOut, 1xRS232",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 2xIn, 2xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 2xIn, 2xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital 2xIn, 2xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-IO Digital Logger 6xIn, 6xOut",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"lessThan": "3.70",
|
|
"status": "affected",
|
|
"version": "0",
|
|
"versionType": "semver"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph 2x",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph 8x",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph NTC",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph NTC PoE",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph Pt100 / Pt1000",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph Pt100 / Pt1000 PoE",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermograph Relais",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermo-Hygrobarograph",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "Web-Thermo-Hygrograph",
|
|
"vendor": "Wiesemann & Theis",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "all"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact.<br>"
|
|
}
|
|
],
|
|
"value": "An low privileged remote Attacker can execute arbitrary web scripts or HTML via a crafted payload injected into several fields of the configuration webpage with limited impact."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "NONE",
|
|
"baseScore": 5.4,
|
|
"baseSeverity": "MEDIUM",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "REQUIRED",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:N",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-79",
|
|
"description": "CWE-79 Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
|
|
"shortName": "CERTVDE",
|
|
"dateUpdated": "2025-05-06T08:01:58.965Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"url": "https://cert.vde.com/en/advisories/VDE-2025-032"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "VDE-2025-032",
|
|
"defect": [
|
|
"CERT@VDE#641768"
|
|
],
|
|
"discovery": "UNKNOWN"
|
|
},
|
|
"title": "Wiesemann & Theis: Multiple W&T Products are vulnerable to cross-site-scripting",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.1.0-dev"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-05-06T13:52:10.556193Z",
|
|
"id": "CVE-2025-3020",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-05-06T13:52:19.548Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |