Files
vuln-cve/data/2025/30xxx/CVE-2025-30240.json
T

581 lines
24 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-30240",
"assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"state": "PUBLISHED",
"assignerShortName": "TPLink",
"dateReserved": "2025-03-19T11:09:33.245Z",
"datePublished": "2026-08-10T22:25:41.776Z",
"dateUpdated": "2026-08-12T18:18:18.691Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
"shortName": "TPLink",
"dateUpdated": "2026-08-10T22:25:41.776Z"
},
"title": "Arbitrary File Read via Improper Symlink Handling in USB HTTPS Access Path in multiple TP-Link Aginet Devices",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-59",
"description": "CWE-59: Improper Link Resolution Before File Access",
"type": "CWE"
}
]
}
],
"impacts": [
{
"capecId": "CAPEC-132",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-132: Symlink Attack"
}
]
}
],
"affected": [
{
"vendor": "TP-Link Systems Inc.",
"product": "HB810(US2) V1.0/1.6/2.0/2.6",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.9.0 3.2.2 v6095.0 Build 260717 Rel.67188n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB810(EU1) V2.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.10.0 3.2.2 v6095.0 Build 260306 Rel.47567n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB710(US2) V1.6/1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB710(EU1) 1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.3.0 3.0.0 v60be.0 Build 251128 Rel.43956n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB610(US2) V2.6/2.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.6.0 3.0.0 v60af.0 Build 251204 Rel.20362n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB610(EU1)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.6.0 3.0.0 v60af.0 Build 251204 Rel.20362n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB610(CA) V2.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.6.0 3.0.0 v60af.0 Build 251216 Rel.46954n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB410( EU1) 1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.3.0 3.0.0 v60bf.0 Build 250901 Rel.45574n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB210(US2) 1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.2.0 3.0.0 v60f9.0 Build 250826 Rel.47715n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB210(EU1) 1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.2.0 3.0.0 v60f9.0 Build 250826 Rel.47715n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB210 Pro(EU1)1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.5.0 3.0.0 v60d5.0 Build 250922 Rel.13742n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "HB210 Pro(US2)1.0/1.6",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.8.0 3.0.0 v60d5.0 Build 260318 Rel.78363n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EB810v(EU1) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.6.0 3.0.0 v608b.0 Build 250613 Rel.10497n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX220(BR) V1.0/1.20/1.28/1.29/1.8",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX220(BR) V2.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.19.0 2.0.0 v609b.0 Build 250814 Rel.49732n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX220(EU1) V1.0/1.20",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX220(RU) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX220(US1) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX222(EU1) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX222(KR) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v609b.0 Build 260427 Rel.16915",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX222(US1) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.20.0 2.0.0 v605f.0 Build 250305 Rel.14728n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX520v(EU1)1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.1.0 3.0.0 v60ee.0 Build 250310 Rel.55637n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX820v(EU1) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.4.0 3.1.9 v6087.0 Build 250928 Rel.59674n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "EX920(US2) V1.6/V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.8.0 3.2.2 v6080.0 Build 260309 Rel.54790n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "XC220-G3v(EU1) V2.30",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.16.0 0.8.0 v6062.0 Build 250817 Rel.23310n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "XC220-G3v(US1) V2.30",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "1.16.0 0.8.0 v6062.0 Build 250817 Rel.23310n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "XX530v(BR)v1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.6.0 3.0.0 v6096.0 Build 250416 Rel.26048n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "XX530v(BR)v2.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.4.0 3.1.10 v60dc.0 Build 250520 Rel.69748n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "XX530v(US1)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.6.0 3.0.0 v6096.0 Build 250416 Rel.26048n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "XX530v(EU1)",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.3.0 3.1.10 v6107.0 Build 250425 Rel.71973n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "VX800v(DE) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "800.0.16",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "VX1800v(EU1) V1.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.14.0 2.0.0 v6092.0 Build 250417 Rel.24761n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
},
{
"vendor": "TP-Link Systems Inc.",
"product": "VX420-G2h(AU) V3.0",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "0.2.0 2.0.0 v60df.0 Build 250427 Rel.38233n",
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"descriptions": [
{
"lang": "en",
"value": "The affected TP-Link Aginet devices do not properly validate symbolic links created on external USB storage\ndevices. By placing a crafted symbolic link on supported storage media, an\nattacker may cause the system to resolve the link.\n\n\n\n\n\n\n\n\n\nSuccessful\nexploitation may allow unauthorized read access to sensitive files within the\ndevice filesystem.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<p>The affected TP-Link Aginet devices do not properly validate symbolic links created on external USB storage\ndevices. By placing a crafted symbolic link on supported storage media, an\nattacker may cause the system to resolve the link.</p><p>\n\n</p><p>Successful\nexploitation may allow unauthorized read access to sensitive files within the\ndevice filesystem.</p>"
}
]
}
],
"references": [
{
"url": "https://www.tp-link.com/us/support/faq/5239/",
"name": "TP-Link Security Advisory",
"tags": [
"vendor-advisory"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "PHYSICAL",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "NONE",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "MEDIUM",
"baseScore": 5.1,
"vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N"
}
}
],
"credits": [
{
"lang": "en",
"value": "Gerhard Hechenberger, Stefan Schweighofer, Constantin Schieber-Knoebl from the SEC Consult Vulnerability Lab",
"type": "finder"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 1.0.4"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-08-12T18:18:03.157977Z",
"id": "CVE-2025-30240",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-08-12T18:18:18.691Z"
}
}
]
}
}