Files
vuln-cve/data/2025/30xxx/CVE-2025-30199.json
T

209 lines
7.8 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-30199",
"assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"state": "PUBLISHED",
"assignerShortName": "cisa-cg",
"dateReserved": "2025-03-18T15:53:08.738Z",
"datePublished": "2025-09-05T17:45:07.227Z",
"dateUpdated": "2025-09-08T18:21:06.626Z"
},
"containers": {
"cna": {
"descriptions": [
{
"lang": "en",
"value": "ECOVACS vacuum robot base stations do not validate firmware updates, so malicious over-the-air updates can be sent to base station via insecure connection between robot and base station."
}
],
"affected": [
{
"vendor": "ECOVACS",
"product": "DEEBOT X1 Series",
"defaultStatus": "unknown",
"versions": [
{
"version": "*",
"status": "affected"
}
]
},
{
"vendor": "ECOVACS",
"product": "DEEBOT T20 Series",
"defaultStatus": "unknown",
"versions": [
{
"version": "*",
"status": "affected"
}
]
},
{
"vendor": "ECOVACS",
"product": "DEEBOT T10 Series",
"defaultStatus": "unknown",
"versions": [
{
"version": "*",
"status": "affected"
}
]
},
{
"vendor": "ECOVACS",
"product": "DEEBOT T30 Series",
"defaultStatus": "unknown",
"versions": [
{
"version": "*",
"status": "affected"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE",
"cweId": "CWE-494"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"scope": "UNCHANGED",
"version": "3.1",
"baseScore": 7.2,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"integrityImpact": "HIGH",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"availabilityImpact": "HIGH",
"privilegesRequired": "HIGH",
"confidentialityImpact": "HIGH"
}
},
{
"cvssV4_0": {
"version": "4.0",
"baseScore": 7.5,
"attackVector": "NETWORK",
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"userInteraction": "NONE",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"privilegesRequired": "HIGH",
"subIntegrityImpact": "NONE",
"vulnIntegrityImpact": "HIGH",
"subAvailabilityImpact": "NONE",
"vulnAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH"
}
},
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-09-08T18:09:57.869806Z",
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "ECOVACS Vacuum and Base Station accept unsigned firmware",
"references": [
{
"name": "url",
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-135-19"
},
{
"name": "url",
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-135-19.json"
},
{
"name": "url",
"url": "https://www.cve.org/CVERecord?id=CVE-2025-30199"
}
],
"credits": [
{
"value": "Dennis Giese, undefined",
"lang": "en"
},
{
"value": "Braelynn Luedtke, undefined",
"lang": "en"
},
{
"value": "Chris Anderson, undefined",
"lang": "en"
}
],
"datePublic": "2025-07-09T00:00:00.000Z",
"providerMetadata": {
"orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
"shortName": "cisa-cg",
"dateUpdated": "2025-09-08T18:10:36.047Z"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-09-08T18:20:48.723390Z",
"id": "CVE-2025-30199",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-09-08T18:21:06.626Z"
}
}
]
}
}