"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-30053",
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"state": "PUBLISHED",
"assignerShortName": "CERT-PL",
"dateReserved": "2025-03-14T14:55:05.985Z",
"datePublished": "2026-10-23T08:22:59.026Z",
"dateUpdated": "2026-10-28T20:02:52.259Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL",
"dateUpdated": "2026-10-28T13:37:54.905Z"
},
"title": "Missing Authentication in CGM CLININET",
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"type": "CWE"
}
]
}
],
"affected": [
{
"vendor": "CGM",
"product": "CGM CLININET",
"modules": [
"cgm-updater"
],
"versions": [
{
"status": "affected",
"version": "0",
"lessThanOrEqual": "2026.MS3",
"changes": [
{
"at": "updater-upkg module update to version 5.3.0",
"status": "unaffected"
}
],
"versionType": "custom"
}
],
"defaultStatus": "unaffected"
}
],
"cpeApplicability": [
{
"operator": "OR",
"nodes": [
{
"operator": "OR",
"negate": false,
"cpeMatch": [
{
"vulnerable": true,
"criteria": "cpe:2.3:a:cgm:cgm_clininet:*:*:*:*:*:*:*:*",
"versionStartIncluding": "0",
"versionEndIncluding": "2026.ms3"
}
]
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The CGM CLININET application runs the cgm-updater process listening on an open network port without any authentication.\n\n\n\n\nThe vulnerability was confirmed to affect versions up to 2026.MS3. Version 2026.MS3 with the updater-upkg component in version 5.3.0 or higher is not affected by this vulnerability.",
"supportingMedia": [
{
"type": "text/html",
"base64": false,
"value": "<div>The CGM CLININET application runs the cgm-updater process listening on an open network port without any authentication.</div><div><br></div><div>The vulnerability was confirmed to affect versions up to&nbsp;2026.MS3.&nbsp;<span>Version&nbsp;</span>2026.MS3<span>&nbsp;with the updater-upkg component in version 5.3.0 or higher is not affected by this vulnerability.</span></div>"
}
]
}
],
"references": [
{
"url": "https://cert.pl/en/posts/2026/10/CVE-2025-30043/",
"tags": [
"third-party-advisory"
]
},
{
"url": "https://www.cgm.com/pol_pl/products/szpital/cgm-clininet.html",
"tags": [
"product"
]
}
],
"metrics": [
{
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
],
"cvssV4_0": {
"attackVector": "NETWORK",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"privilegesRequired": "NONE",
"userInteraction": "NONE",
"vulnConfidentialityImpact": "LOW",
"subConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"subIntegrityImpact": "NONE",
"vulnAvailabilityImpact": "LOW",
"subAvailabilityImpact": "NONE",
"exploitMaturity": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"valueDensity": "NOT_DEFINED",
"vulnerabilityResponseEffort": "NOT_DEFINED",
"providerUrgency": "NOT_DEFINED",
"version": "4.0",
"baseSeverity": "MEDIUM",
"baseScore": 6.9,
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N"
}
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2026-10-28T18:23:49.715395Z",
"id": "CVE-2025-30053",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2026-10-28T20:02:52.259Z"
}
}
]
}
}