Files
vuln-cve/data/2025/27xxx/CVE-2025-27254.json
T

145 lines
5.6 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-27254",
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"state": "PUBLISHED",
"assignerShortName": "Nozomi",
"dateReserved": "2025-02-21T08:32:26.973Z",
"datePublished": "2025-03-10T09:05:08.963Z",
"dateUpdated": "2025-10-07T14:18:35.592Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EnerVista UR Setup",
"vendor": "GE Vernova",
"versions": [
{
"status": "affected",
"version": "8.42",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-282 \"Improper Ownership Management\"&nbsp;in GE Vernova EnerVista UR Setup allows Authentication Bypass.&nbsp;<br><span style=\"background-color: var(--wht);\">The software's startup authentication can be disabled by altering a Windows registry setting that any user can modify.</span><br><br>"
}
],
"value": "CWE-282 \"Improper Ownership Management\" in GE Vernova EnerVista UR Setup allows Authentication Bypass. \nThe software's startup authentication can be disabled by altering a Windows registry setting that any user can modify."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-282",
"description": "CWE-282 Improper Ownership Management",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi",
"dateUpdated": "2025-10-07T14:18:35.592Z"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27254"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-03-10T14:10:30.949201Z",
"id": "CVE-2025-27254",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-03-10T14:10:54.966Z"
}
}
]
}
}