Files
vuln-cve/data/2025/27xxx/CVE-2025-27253.json
T

393 lines
15 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-27253",
"assignerOrgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"state": "PUBLISHED",
"assignerShortName": "Nozomi",
"dateReserved": "2025-02-21T08:32:26.973Z",
"datePublished": "2025-03-10T09:04:34.413Z",
"dateUpdated": "2025-10-07T14:16:49.710Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "N60 multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "B30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "B90 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C70 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "C95 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "D30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "D60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "F35 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "F60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "G60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L30 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "L90 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "M60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "T35 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "T60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "M60 Multilin",
"vendor": "GE Vernova",
"versions": [
{
"lessThanOrEqual": "8.60",
"status": "affected",
"version": "7.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A CWE-15 \"External Control of System or Configuration Setting\" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
}
],
"value": "A CWE-15 \"External Control of System or Configuration Setting\" in GE Vernova UR IED family devices from version 7.0 up to 8.60 allows an attacker to provide input that establishes a TCP connection through a port forwarding. The lack of the IP address and port validation may allow the attacker to bypass firewall rules or to send malicious traffic in the network."
}
],
"impacts": [
{
"capecId": "CAPEC-1",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-1 Accessing Functionality Not Properly Constrained by ACLs"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-15",
"description": "CWE-15 External Control of System or Configuration Setting",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "bec8025f-a851-46e5-b3a3-058e6b0aa23c",
"shortName": "Nozomi",
"dateUpdated": "2025-10-07T14:16:49.710Z"
},
"references": [
{
"url": "https://www.gevernova.com/grid-solutions/app/DownloadFile.aspx?prod=urfamily&type=21&file=76"
},
{
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2025-27253"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-03-10T15:33:39.489617Z",
"id": "CVE-2025-27253",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-03-10T15:33:49.185Z"
}
}
]
}
}