Files
vuln-cve/data/2025/1xxx/CVE-2025-1960.json
T

130 lines
5.3 KiB
JSON
Raw Blame History

This file contains ambiguous Unicode characters
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2025-1960",
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"state": "PUBLISHED",
"assignerShortName": "schneider",
"dateReserved": "2025-03-04T16:25:22.129Z",
"datePublished": "2025-03-12T15:33:59.173Z",
"dateUpdated": "2025-03-13T18:32:42.467Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "WebHMI – Deployed with EcoStruxure Power Automation System",
"vendor": "Schneider Electric",
"versions": [
{
"status": "affected",
"version": "WebHMI v4.1.0.0 and prior when deployed with EPAS User Interface 2.6.30.19 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an\nattacker to execute unauthorized commands when a system’s default password credentials have not been\nchanged on first use. The default username is not displayed correctly in the WebHMI interface. \n\n<br>"
}
],
"value": "CWE-1188: Initialization of a Resource with an Insecure Default vulnerability exists that could cause an\nattacker to execute unauthorized commands when a system’s default password credentials have not been\nchanged on first use. The default username is not displayed correctly in the WebHMI interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1188",
"description": "CWE-1188 Insecure Default Initialization of Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider",
"dateUpdated": "2025-03-13T18:32:42.467Z"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-070-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-070-03.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-03-12T15:56:56.322926Z",
"id": "CVE-2025-1960",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-03-12T15:57:18.555Z"
}
}
]
}
}