Files
vuln-cve/data/2025/14xxx/CVE-2025-14097.json
T

258 lines
16 KiB
JSON
Raw Blame History

This file contains invisible Unicode characters
This file contains invisible Unicode characters that are indistinguishable to humans but may be processed differently by a computer. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
This file contains Unicode characters that might be confused with other characters. If you think that this is intentional, you can safely ignore this warning. Use the Escape button to reveal them.
{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-14097",
"assignerOrgId": "46b595e9-1acc-41cb-9398-adaf98d37a9b",
"state": "PUBLISHED",
"assignerShortName": "Radiometer",
"dateReserved": "2025-12-05T10:50:03.683Z",
"datePublished": "2025-12-17T12:36:03.779Z",
"dateUpdated": "2025-12-17T14:41:13.252Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "ABL90 FLEX and ABL90 FLEX PLUS Analyzers",
"vendor": "Radiometer Medical Aps",
"versions": [
{
"status": "affected",
"version": "Application software versions < 3.5MR11 with Windows 7, Windows XP operating systems",
"versionType": "ABL90 DMS (Data Management system)"
},
{
"status": "unaffected",
"version": "Application software versions >= 3.5MR11 with Windows 10 operating system",
"versionType": "ABL90 DMS (Data Management system)"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ABL800 BASIC and ABL800 FLEX Analyzers",
"vendor": "Radiometer Medical Aps",
"versions": [
{
"status": "affected",
"version": "Application software versions < 6.20MR2 with Windows 7, Windows XP operating systems",
"versionType": "ABL800 DMS(Data Management System)"
},
{
"status": "unaffected",
"version": "Application software versions >= 6.20MR2 with Windows 10 operating system",
"versionType": "ABL800 DMS(Data Management System)"
}
]
},
{
"defaultStatus": "unaffected",
"product": "AQT90 FLEX Analyzers",
"vendor": "Radiometer Medical Aps",
"versions": [
{
"status": "affected",
"version": "Application software versions <= 8.13 MR2 with Windows 7, Windows XP operating systems",
"versionType": "AQT90 DMS (Data Management System)"
},
{
"status": "unaffected",
"version": "Application software versions >= 8.13 MR2 with Windows 10 operating system",
"versionType": "AQT90 DMS (Data Management System)"
}
]
}
],
"configurations": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Affected application software version is in use AND Remote support feature is enabled in the Analyzer.\n\n<br>"
}
],
"value": "Affected application software version is in use AND Remote support feature is enabled in the Analyzer."
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Florian Hauser and Fabian Weber from CODE WHITE GmbH"
}
],
"datePublic": "2025-12-17T12:35:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; Other related CVE's are CVE-2025-14095 &amp; CVE-2025-14096.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; <span style=\"background-color: rgb(255, 255, 255);\">Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.</span>\n\n<br><br>Required Configuration for Exposure:&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">Affected application software version is in use and remote support feature is enabled in the analyzer.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; </span>Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;Permanent solution:<br>Customers should ensure the following:<br>• The network is secure, and access follows best practices.<br>Local Radiometer representatives will contact all affected customers to discuss a permanent solution.&nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp; &nbsp;<br>Exploit Status:<br>\n\n<span style=\"background-color: rgb(255, 255, 255);\">Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.</span>\n\n<br>"
}
],
"value": "A vulnerability in the application software of multiple Radiometer products may allow remote code execution and unauthorized device management when specific internal conditions are met. Exploitation requires that a remote connection is established with additional information obtained through other means. The issue is caused by a weakness in the analyzer’s application software.                                                                                                                                                                                                Other related CVE's are CVE-2025-14095 & CVE-2025-14096.                                                                                                      Affected customers have been informed about this vulnerability. This CVE is being published to provide transparency.\n\n\n\nRequired Configuration for Exposure: Affected application software version is in use and remote support feature is enabled in the analyzer.                                                                                                                                                                        Temporary work Around: If the network is not considered secure, please remove the analyzer from the network.                         Permanent solution:\nCustomers should ensure the following:\n• The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution.                                                     \nExploit Status:\n\n\nResearchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication."
}
],
"exploits": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication.\n\n<br>"
}
],
"value": "Researchers have provided working proof-of-concept (PoC). Radiometer is not aware of any publicly available exploits at the time of this publication."
}
],
"impacts": [
{
"capecId": "CAPEC-555",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-555: Remote Services with Stolen Credentials"
}
]
},
{
"capecId": "CAPEC-653",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-653: Use of Known Operating System Credentials"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287: Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "46b595e9-1acc-41cb-9398-adaf98d37a9b",
"shortName": "Radiometer",
"dateUpdated": "2025-12-17T13:14:55.334Z"
},
"references": [
{
"url": "https://www.radiometer.com/myradiometer"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Customers should ensure the following:<br>• The network is secure, and access follows best practices.<br>Local Radiometer representatives will contact all affected customers to discuss a permanent solution.\n\n\n\n<br>"
}
],
"value": "Customers should ensure the following:\n• The network is secure, and access follows best practices.\nLocal Radiometer representatives will contact all affected customers to discuss a permanent solution."
}
],
"source": {
"discovery": "EXTERNAL"
},
"timeline": [
{
"lang": "en",
"time": "2025-12-17T12:35:00.000Z",
"value": "CVE Published"
}
],
"title": "Remote Code Execution Vulnerability in Radiometer Products",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "If the network is not considered secure, please remove the analyzer from the network."
}
],
"value": "If the network is not considered secure, please remove the analyzer from the network."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-12-17T14:40:30.048229Z",
"id": "CVE-2025-14097",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-12-17T14:41:13.252Z"
}
}
]
}
}