238 lines
10 KiB
JSON
238 lines
10 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.2",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2025-12357",
|
|
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "icscert",
|
|
"dateReserved": "2025-10-27T16:05:18.413Z",
|
|
"datePublished": "2025-10-31T15:33:48.343Z",
|
|
"dateUpdated": "2026-03-18T20:07:29.329Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
|
"shortName": "icscert",
|
|
"dateUpdated": "2026-03-17T16:05:30.393Z"
|
|
},
|
|
"title": "International Standards Organization ISO 15118-2 Improper Restriction of Communication Channel to Intended Endpoints",
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-923",
|
|
"description": "CWE-923",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "ISO 15118-2 Network and Application Protocol Requirements",
|
|
"product": "EV Car Chargers",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "Part 15118-2 Network and Application Protocol Requirements"
|
|
}
|
|
],
|
|
"defaultStatus": "unaffected"
|
|
}
|
|
],
|
|
"cpeApplicability": [
|
|
{
|
|
"nodes": [
|
|
{
|
|
"cpeMatch": [
|
|
{
|
|
"criteria": "cpe:2.3:a:iso_15118-2_network_and_application_protocol_requirements:ev_car_chargers:part_15118-2_network_and_application_protocol_requirements:*:*:*:*:*:*:*",
|
|
"vulnerable": true
|
|
}
|
|
],
|
|
"negate": false,
|
|
"operator": "OR"
|
|
}
|
|
],
|
|
"operator": "OR"
|
|
}
|
|
],
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "By manipulating the Signal Level Attenuation Characterization (SLAC) \nprotocol with spoofed measurements, an attacker can stage a \nman-in-the-middle attack between an electric vehicle and chargers that \ncomply with the ISO 15118-2 part. This vulnerability may be exploitable \nwirelessly, within close proximity, via electromagnetic induction.",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "By manipulating the Signal Level Attenuation Characterization (SLAC) \nprotocol with spoofed measurements, an attacker can stage a \nman-in-the-middle attack between an electric vehicle and chargers that \ncomply with the ISO 15118-2 part. This vulnerability may be exploitable \nwirelessly, within close proximity, via electromagnetic induction."
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://www.iec.ch/contact?id=40499"
|
|
},
|
|
{
|
|
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-303-01"
|
|
},
|
|
{
|
|
"url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2025/icsa-25-303-01.json"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"attackVector": "ADJACENT_NETWORK",
|
|
"attackComplexity": "LOW",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"scope": "UNCHANGED",
|
|
"confidentialityImpact": "LOW",
|
|
"integrityImpact": "LOW",
|
|
"availabilityImpact": "LOW",
|
|
"baseSeverity": "MEDIUM",
|
|
"baseScore": 6.3,
|
|
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L"
|
|
}
|
|
},
|
|
{
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
],
|
|
"cvssV4_0": {
|
|
"attackVector": "ADJACENT",
|
|
"attackComplexity": "LOW",
|
|
"attackRequirements": "NONE",
|
|
"privilegesRequired": "NONE",
|
|
"userInteraction": "NONE",
|
|
"vulnConfidentialityImpact": "LOW",
|
|
"subConfidentialityImpact": "NONE",
|
|
"vulnIntegrityImpact": "LOW",
|
|
"subIntegrityImpact": "NONE",
|
|
"vulnAvailabilityImpact": "LOW",
|
|
"subAvailabilityImpact": "NONE",
|
|
"exploitMaturity": "NOT_DEFINED",
|
|
"Safety": "NOT_DEFINED",
|
|
"Automatable": "NOT_DEFINED",
|
|
"Recovery": "NOT_DEFINED",
|
|
"valueDensity": "NOT_DEFINED",
|
|
"vulnerabilityResponseEffort": "NOT_DEFINED",
|
|
"providerUrgency": "NOT_DEFINED",
|
|
"version": "4.0",
|
|
"baseSeverity": "MEDIUM",
|
|
"baseScore": 5.3,
|
|
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N"
|
|
}
|
|
},
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CNA",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"workarounds": [
|
|
{
|
|
"lang": "en",
|
|
"value": "ISO recommends using TLS for all communications in accordance with \nISO 15118-20. While the use of TLS is recommended in ISO 15118-2, it is \nrequired in the ISO 15118-20 revision. TLS should be implemented with \ncertificate chaining.\n\nFor additional information, please contact the International Electrotechnical Commission https://www.iec.ch/contact .",
|
|
"supportingMedia": [
|
|
{
|
|
"type": "text/html",
|
|
"base64": false,
|
|
"value": "<p>ISO recommends using TLS for all communications in accordance with \nISO 15118-20. While the use of TLS is recommended in ISO 15118-2, it is \nrequired in the ISO 15118-20 revision. TLS should be implemented with \ncertificate chaining.</p><p>For additional information, please contact the <a target=\"_blank\" rel=\"nofollow\" href=\"https://www.iec.ch/contact?id=40499\">International Electrotechnical Commission</a>.\n\n<br></p>"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"credits": [
|
|
{
|
|
"lang": "en",
|
|
"value": "Mark I. Johnson of Southwest Research Institute reported this vulnerability to CISA.",
|
|
"type": "finder"
|
|
},
|
|
{
|
|
"lang": "en",
|
|
"value": "Sébastien Dudek of Penthertz disclosed this vulnerability publicly.",
|
|
"type": "finder"
|
|
},
|
|
{
|
|
"lang": "en",
|
|
"value": "Jean-Christophe Delaunay and Vincent Fargues of Synacktiv disclosed this vulnerability publicly.",
|
|
"type": "finder"
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "ICSA-25-303-01",
|
|
"discovery": "EXTERNAL"
|
|
},
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.4.0"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2026-03-18T20:07:24.050954Z",
|
|
"id": "CVE-2025-12357",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2026-03-18T20:07:29.329Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |