Files
vuln-cve/data/2025/11xxx/CVE-2025-11546.json
T

146 lines
6.2 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2025-11546",
"assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"state": "PUBLISHED",
"assignerShortName": "NEC",
"dateReserved": "2025-10-09T06:48:19.068Z",
"datePublished": "2025-11-07T01:09:08.662Z",
"dateUpdated": "2025-11-07T18:29:57.236Z"
},
"containers": {
"cna": {
"affected": [
{
"product": "CLUSTERPRO X for Linux (EXPRESSCLUSTER X for Linux)",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "4.0, 4.1, 4.2, 5.0, 5.1 and 5.2"
}
]
},
{
"product": "CLUSTERPRO X SingleServerSafe for Linux (EXPRESSCLUSTER X SingleServerSafe for Linux)",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "4.0, 4.1, 4.2, 5.0, 5.1 and 5.2"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication."
}
],
"value": "CLUSTERPRO X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 and EXPRESSCLUSTER X for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, CLUSTERPRO X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2, EXPRESSCLUSTER X SingleServerSafe for Linux 4.0, 4.1, 4.2, 5.0, 5.1 and 5.2 allows an attacker sends specially crafted network packets to the product, arbitrary OS commands may be executed without authentication."
}
],
"metrics": [
{
"cvssV4_0": {
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.3,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"shortName": "NEC",
"dateUpdated": "2025-11-07T04:04:50.054Z"
},
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv25-006_en.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-11-07T18:29:04.715150Z",
"id": "CVE-2025-11546",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-11-07T18:29:57.236Z"
}
}
]
}
}