195 lines
7.9 KiB
JSON
195 lines
7.9 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2025-0593",
|
|
"assignerOrgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "SICK AG",
|
|
"dateReserved": "2025-01-20T06:40:50.034Z",
|
|
"datePublished": "2025-02-14T20:18:42.184Z",
|
|
"dateUpdated": "2025-02-14T21:59:58.197Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"affected": [
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "SICK Lector8xx",
|
|
"vendor": "SICK AG",
|
|
"versions": [
|
|
{
|
|
"lessThan": "2.4.0",
|
|
"status": "affected",
|
|
"version": "0",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
},
|
|
{
|
|
"defaultStatus": "unaffected",
|
|
"product": "SICK InspectorP8xx",
|
|
"vendor": "SICK AG",
|
|
"versions": [
|
|
{
|
|
"lessThan": "3.11.1",
|
|
"status": "affected",
|
|
"version": "0",
|
|
"versionType": "custom"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"datePublic": "2025-02-14T20:15:00.000Z",
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by using lower-level functions to interact with the device."
|
|
}
|
|
],
|
|
"value": "The vulnerability may allow a remote low priviledged attacker to run arbitrary shell commands by using lower-level functions to interact with the device."
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"attackComplexity": "LOW",
|
|
"attackVector": "NETWORK",
|
|
"availabilityImpact": "HIGH",
|
|
"baseScore": 8.8,
|
|
"baseSeverity": "HIGH",
|
|
"confidentialityImpact": "HIGH",
|
|
"integrityImpact": "HIGH",
|
|
"privilegesRequired": "LOW",
|
|
"scope": "UNCHANGED",
|
|
"userInteraction": "NONE",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
|
|
"version": "3.1"
|
|
},
|
|
"format": "CVSS",
|
|
"scenarios": [
|
|
{
|
|
"lang": "en",
|
|
"value": "GENERAL"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"cweId": "CWE-77",
|
|
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command ('Command Injection')",
|
|
"lang": "en",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"providerMetadata": {
|
|
"orgId": "a6863dd2-93fc-443d-bef1-79f0b5020988",
|
|
"shortName": "SICK AG",
|
|
"dateUpdated": "2025-02-14T20:18:42.184Z"
|
|
},
|
|
"references": [
|
|
{
|
|
"tags": [
|
|
"x_SICK PSIRT Website"
|
|
],
|
|
"url": "https://sick.com/psirt"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_ICS-CERT recommended practices on Industrial Security"
|
|
],
|
|
"url": "https://cdn.sick.com/media/docs/1/11/411/Special_information_CYBERSECURITY_BY_SICK_en_IM0084411.PDF"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_ICS-CERT recommended practices on Industrial Security"
|
|
],
|
|
"url": "https://www.cisa.gov/resources-tools/resources/ics-recommended-practices"
|
|
},
|
|
{
|
|
"tags": [
|
|
"x_CVSS v3.1 Calculator"
|
|
],
|
|
"url": "https://www.first.org/cvss/calculator/3.1"
|
|
},
|
|
{
|
|
"tags": [
|
|
"vendor-advisory"
|
|
],
|
|
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0002.pdf"
|
|
},
|
|
{
|
|
"tags": [
|
|
"vendor-advisory",
|
|
"x_csaf"
|
|
],
|
|
"url": "https://www.sick.com/.well-known/csaf/white/2025/sca-2025-0002.json"
|
|
}
|
|
],
|
|
"solutions": [
|
|
{
|
|
"lang": "en",
|
|
"supportingMedia": [
|
|
{
|
|
"base64": false,
|
|
"type": "text/html",
|
|
"value": "Users are strongly recommended to upgrade to the latest release of the Lector8xx (>=2.4.0)\nand the InspectorP8xx (>=3.11.1) respectively that includes a patch for the vulnerability. It is also\nrecommended to set a secure password, please refer to the respective operating instructions, linked in\nthe reference section."
|
|
}
|
|
],
|
|
"value": "Users are strongly recommended to upgrade to the latest release of the Lector8xx (>=2.4.0)\nand the InspectorP8xx (>=3.11.1) respectively that includes a patch for the vulnerability. It is also\nrecommended to set a secure password, please refer to the respective operating instructions, linked in\nthe reference section."
|
|
}
|
|
],
|
|
"source": {
|
|
"advisory": "SCA-2025-0002",
|
|
"discovery": "INTERNAL"
|
|
},
|
|
"title": "SICK Lector8xx and InspectorP8xx vulnerable for code execution",
|
|
"x_generator": {
|
|
"engine": "Vulnogram 0.2.0"
|
|
}
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-02-14T21:39:56.334389Z",
|
|
"id": "CVE-2025-0593",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-02-14T21:59:58.197Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |