283 lines
13 KiB
JSON
283 lines
13 KiB
JSON
{
|
||
"dataType": "CVE_RECORD",
|
||
"dataVersion": "5.1",
|
||
"cveMetadata": {
|
||
"cveId": "CVE-2024-7847",
|
||
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
|
||
"state": "PUBLISHED",
|
||
"assignerShortName": "Rockwell",
|
||
"dateReserved": "2024-08-15T15:51:22.233Z",
|
||
"datePublished": "2024-10-14T13:47:14.540Z",
|
||
"dateUpdated": "2024-10-15T14:05:45.670Z"
|
||
},
|
||
"containers": {
|
||
"cna": {
|
||
"affected": [
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "RSLogix 500®",
|
||
"vendor": "Rockwell Automation",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "All"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "RSLogix™ Micro Developer and Starter",
|
||
"vendor": "Rockwell Automation",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "All"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "RSLogix™ 5",
|
||
"vendor": "Rockwell Automation",
|
||
"versions": [
|
||
{
|
||
"status": "affected",
|
||
"version": "All"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"type": "reporter",
|
||
"value": "Sharon Brizinov of Claroty Research - Team82"
|
||
}
|
||
],
|
||
"datePublic": "2024-09-19T13:00:00.000Z",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "<p><b>VULNERABILITY DETAILS</b></p><p>Rockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. </p><p>A feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability.</p>"
|
||
}
|
||
],
|
||
"value": "VULNERABILITY DETAILS\n\nRockwell Automation used the latest versions of the CVSS scoring system to assess the following vulnerabilities. The following vulnerabilities were reported to us by Sharon Brizinov of Claroty Research - Team82. \n\nA feature in the affected products enables users to prepare a project file with an embedded VBA script and can be configured to run once the project file has been opened without user intervention. This feature can be abused to trick a legitimate user into executing malicious code upon opening an infected RSP/RSS project file. If exploited, a threat actor may be able to perform a remote code execution. Connected devices may also be impacted by exploitation of this vulnerability."
|
||
}
|
||
],
|
||
"impacts": [
|
||
{
|
||
"capecId": "CAPEC-19",
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"value": "CAPEC-19 Embedding Scripts within Scripts"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV4_0": {
|
||
"Automatable": "NOT_DEFINED",
|
||
"Recovery": "NOT_DEFINED",
|
||
"Safety": "NOT_DEFINED",
|
||
"attackComplexity": "HIGH",
|
||
"attackRequirements": "NONE",
|
||
"attackVector": "LOCAL",
|
||
"baseScore": 8.8,
|
||
"baseSeverity": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"providerUrgency": "NOT_DEFINED",
|
||
"subAvailabilityImpact": "HIGH",
|
||
"subConfidentialityImpact": "HIGH",
|
||
"subIntegrityImpact": "HIGH",
|
||
"userInteraction": "PASSIVE",
|
||
"valueDensity": "NOT_DEFINED",
|
||
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
|
||
"version": "4.0",
|
||
"vulnAvailabilityImpact": "HIGH",
|
||
"vulnConfidentialityImpact": "HIGH",
|
||
"vulnIntegrityImpact": "HIGH",
|
||
"vulnerabilityResponseEffort": "NOT_DEFINED"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"cvssV3_1": {
|
||
"attackComplexity": "HIGH",
|
||
"attackVector": "LOCAL",
|
||
"availabilityImpact": "HIGH",
|
||
"baseScore": 7.7,
|
||
"baseSeverity": "HIGH",
|
||
"confidentialityImpact": "HIGH",
|
||
"integrityImpact": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "CHANGED",
|
||
"userInteraction": "REQUIRED",
|
||
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H",
|
||
"version": "3.1"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-345",
|
||
"description": "CWE-345 Insufficient Verification of Data Authenticity",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
|
||
"shortName": "Rockwell",
|
||
"dateUpdated": "2024-10-14T13:47:14.540Z"
|
||
},
|
||
"references": [
|
||
{
|
||
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1701.html"
|
||
}
|
||
],
|
||
"source": {
|
||
"discovery": "EXTERNAL"
|
||
},
|
||
"title": "RSLogix™ 5 and RSLogix 500® Remote Code Execution Via VBA Embedded Script",
|
||
"workarounds": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "<p><b>Mitigations and Workarounds </b></p><p>Users using the affected software are encouraged to apply the following mitigations and security best practices, where possible. </p><p>· Deny the execution feature in FactoryTalk® Administration Console, when not needed, by navigating to “Policies”, selecting ‘”Enable/Disable VBA”, and then checking the “Deny” box to block VBA code execution.</p><p>· Save project files in a Trusted® location where only administrators can modify it and verify file integrity.</p><p>· Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password.</p>"
|
||
}
|
||
],
|
||
"value": "Mitigations and Workarounds \n\nUsers using the affected software are encouraged to apply the following mitigations and security best practices, where possible. \n\n· Deny the execution feature in FactoryTalk® Administration Console, when not needed, by navigating to “Policies”, selecting ‘”Enable/Disable VBA”, and then checking the “Deny” box to block VBA code execution.\n\n· Save project files in a Trusted® location where only administrators can modify it and verify file integrity.\n\n· Utilize the VBA editor protection feature, which locks the VBA code from viewing and editing by setting a password."
|
||
}
|
||
],
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.2.0"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"affected": [
|
||
{
|
||
"vendor": "rockwellautomation",
|
||
"product": "rslogix_500",
|
||
"cpes": [
|
||
"cpe:2.3:a:rockwellautomation:rslogix_500:*:*:*:*:*:*:*:*"
|
||
],
|
||
"defaultStatus": "unknown",
|
||
"versions": [
|
||
{
|
||
"version": "0",
|
||
"status": "affected",
|
||
"lessThan": "*",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"vendor": "rockwellautomation",
|
||
"product": "rslogix_micro_developer",
|
||
"cpes": [
|
||
"cpe:2.3:a:rockwellautomation:rslogix_micro_developer:*:*:*:*:*:*:*:*"
|
||
],
|
||
"defaultStatus": "unknown",
|
||
"versions": [
|
||
{
|
||
"version": "0",
|
||
"status": "affected",
|
||
"lessThan": "*",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"vendor": "rockwellautomation",
|
||
"product": "rslogix_micro_starter",
|
||
"cpes": [
|
||
"cpe:2.3:a:rockwellautomation:rslogix_micro_starter:*:*:*:*:*:*:*:*"
|
||
],
|
||
"defaultStatus": "unknown",
|
||
"versions": [
|
||
{
|
||
"version": "0",
|
||
"status": "affected",
|
||
"lessThan": "*",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"vendor": "rockwellautomation",
|
||
"product": "rslogix_5",
|
||
"cpes": [
|
||
"cpe:2.3:a:rockwellautomation:rslogix_5:*:*:*:*:*:*:*:*"
|
||
],
|
||
"defaultStatus": "unknown",
|
||
"versions": [
|
||
{
|
||
"version": "0",
|
||
"status": "affected",
|
||
"lessThan": "*",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"timestamp": "2024-10-14T15:18:18.670939Z",
|
||
"id": "CVE-2024-7847",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "total"
|
||
}
|
||
],
|
||
"role": "CISA Coordinator",
|
||
"version": "2.0.3"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2024-10-15T14:05:45.670Z"
|
||
}
|
||
}
|
||
]
|
||
}
|
||
} |