"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-6079",
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"state": "PUBLISHED",
"assignerShortName": "Rockwell",
"dateReserved": "2024-06-17T16:43:06.697Z",
"datePublished": "2024-08-13T17:46:24.950Z",
"dateUpdated": "2024-08-21T16:44:29.747Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Emulate3D™",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "17.00.00.13276"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<span style=\"background-color: rgb(255, 255, 255);\">A vulnerability exists in the Rockwell Automation Emulate3D™,&nbsp;which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack.</span>"
}
],
"value": "A vulnerability exists in the Rockwell Automation Emulate3D™, which could be leveraged to execute a DLL Hijacking attack. The application loads shared libraries, which are readable and writable by any user. If exploited, a malicious user could leverage a malicious dll and perform a remote code execution attack."
}
],
"impacts": [
{
"capecId": "CAPEC-124",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-124 Shared Resource Manipulation"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "HIGH",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:L/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-610",
"description": "CWE-610 Externally Controlled Reference to a Resource in Another Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell",
"dateUpdated": "2024-08-13T17:52:52.022Z"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201683.html"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "<p>Customers using the affected software are encouraged to <a target=\"_blank\" rel=\"nofollow\"></a><a target=\"_blank\" rel=\"nofollow\">apply the following risk mitigations</a>&nbsp;, if possible:</p><p>· &nbsp; &nbsp; &nbsp; Update to the corrected software version, 17.00.00.13348.</p><p>· &nbsp; &nbsp; &nbsp; For information on how to mitigate Security Risks on industrial automation control systems, we encourage customers to implement our suggested <a target=\"_blank\" rel=\"nofollow\" href=\"https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight\">security best practices</a>&nbsp;to minimize the risk of the vulnerability.</p>\n\n<br>"
}
],
"value": "Customers using the affected software are encouraged to security best practices https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1085012/loc/en_US#__highlight  to minimize the risk of the vulnerability."
}
],
"source": {
"advisory": "SD1683",
"discovery": "INTERNAL"
},
"title": "DLL Hijacking Vulnerability Exists in Rockwell Automation Emulate3D™",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"affected": [
{
"vendor": "rockwellautomation",
"product": "emulate3d",
"cpes": [
"cpe:2.3:a:rockwellautomation:emulate3d:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "17.00.00.13276",
"status": "affected"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-08-14T13:40:10.955503Z",
"id": "CVE-2024-6079",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-08-21T16:44:29.747Z"
}
}
]
}
}