"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-5597",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2024-06-03T13:32:22.404Z",
"datePublished": "2024-06-10T16:53:50.147Z",
"dateUpdated": "2024-08-01T21:18:06.595Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Monitouch V-SFT",
"vendor": "Fuji Electric",
"versions": [
{
"lessThan": "6.2.3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "kimiya working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Fuji Electric Monitouch V-SFT&nbsp;<span style=\"background-color: rgb(255, 255, 255);\">is vulnerable to a type confusion, which could cause a crash or code execution.</span>\n\n"
}
],
"value": "Fuji Electric Monitouch V-SFT is vulnerable to a type confusion, which could cause a crash or code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-843",
"description": "CWE-843 Type Confusion",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2024-06-10T16:53:50.147Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Fuji Electric recommends users update the product to <a target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd\">Monitouch V-SFT v6.2.3.0</a>.\n\n<br>"
}
],
"value": "Fuji Electric recommends users update the product to Monitouch V-SFT v6.2.3.0 https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd ."
}
],
"source": {
"advisory": "ICSA-24-151-02",
"discovery": "EXTERNAL"
},
"title": "Fuji Electric Monitouch V-SFT Type Confusion",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-06-10T20:11:14.382101Z",
"id": "CVE-2024-5597",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-10T20:12:13.322Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-01T21:18:06.595Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02",
"tags": [
"x_transferred"
]
}
]
}
]
}
}