"affected": [
|
||
{
|
||
"defaultStatus": "unaffected",
|
||
"product": "Monitouch V-SFT",
|
||
"vendor": "Fuji Electric",
|
||
"versions": [
|
||
{
|
||
"lessThan": "6.2.3.0",
|
||
"status": "affected",
|
||
"version": "0",
|
||
"versionType": "custom"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"credits": [
|
||
{
|
||
"lang": "en",
|
||
"type": "finder",
|
||
"value": "kimiya working with Trend Micro Zero Day Initiative, reported these vulnerabilities to CISA."
|
||
}
|
||
],
|
||
"descriptions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "Fuji Electric Monitouch V-SFT <span style=\"background-color: rgb(255, 255, 255);\">is vulnerable to a type confusion, which could cause a crash or code execution.</span>\n\n"
|
||
}
|
||
],
|
||
"value": "Fuji Electric Monitouch V-SFT is vulnerable to a type confusion, which could cause a crash or code execution."
|
||
}
|
||
],
|
||
"metrics": [
|
||
{
|
||
"cvssV3_1": {
|
||
"attackComplexity": "LOW",
|
||
"attackVector": "LOCAL",
|
||
"availabilityImpact": "HIGH",
|
||
"baseScore": 7.8,
|
||
"baseSeverity": "HIGH",
|
||
"confidentialityImpact": "HIGH",
|
||
"integrityImpact": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"scope": "UNCHANGED",
|
||
"userInteraction": "REQUIRED",
|
||
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
||
"version": "3.1"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
},
|
||
{
|
||
"cvssV4_0": {
|
||
"Automatable": "NOT_DEFINED",
|
||
"Recovery": "NOT_DEFINED",
|
||
"Safety": "NOT_DEFINED",
|
||
"attackComplexity": "LOW",
|
||
"attackRequirements": "NONE",
|
||
"attackVector": "LOCAL",
|
||
"baseScore": 8.5,
|
||
"baseSeverity": "HIGH",
|
||
"privilegesRequired": "NONE",
|
||
"providerUrgency": "NOT_DEFINED",
|
||
"subAvailabilityImpact": "NONE",
|
||
"subConfidentialityImpact": "NONE",
|
||
"subIntegrityImpact": "NONE",
|
||
"userInteraction": "PASSIVE",
|
||
"valueDensity": "NOT_DEFINED",
|
||
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
|
||
"version": "4.0",
|
||
"vulnAvailabilityImpact": "HIGH",
|
||
"vulnConfidentialityImpact": "HIGH",
|
||
"vulnIntegrityImpact": "HIGH",
|
||
"vulnerabilityResponseEffort": "NOT_DEFINED"
|
||
},
|
||
"format": "CVSS",
|
||
"scenarios": [
|
||
{
|
||
"lang": "en",
|
||
"value": "GENERAL"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"problemTypes": [
|
||
{
|
||
"descriptions": [
|
||
{
|
||
"cweId": "CWE-843",
|
||
"description": "CWE-843 Type Confusion",
|
||
"lang": "en",
|
||
"type": "CWE"
|
||
}
|
||
]
|
||
}
|
||
],
|
||
"providerMetadata": {
|
||
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
|
||
"shortName": "icscert",
|
||
"dateUpdated": "2024-06-10T16:53:50.147Z"
|
||
},
|
||
"references": [
|
||
{
|
||
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02"
|
||
}
|
||
],
|
||
"solutions": [
|
||
{
|
||
"lang": "en",
|
||
"supportingMedia": [
|
||
{
|
||
"base64": false,
|
||
"type": "text/html",
|
||
"value": "Fuji Electric recommends users update the product to <a target=\"_blank\" rel=\"nofollow\" href=\"https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd\">Monitouch V-SFT v6.2.3.0</a>.\n\n<br>"
|
||
}
|
||
],
|
||
"value": "Fuji Electric recommends users update the product to Monitouch V-SFT v6.2.3.0 https://felib.fujielectric.co.jp/en/M10009/M20104/document_detail/55ff739b-bd06-4241-b078-3b9c9728bdfd ."
|
||
}
|
||
],
|
||
"source": {
|
||
"advisory": "ICSA-24-151-02",
|
||
"discovery": "EXTERNAL"
|
||
},
|
||
"title": "Fuji Electric Monitouch V-SFT Type Confusion",
|
||
"x_generator": {
|
||
"engine": "Vulnogram 0.2.0"
|
||
}
|
||
},
|
||
"adp": [
|
||
{
|
||
"metrics": [
|
||
{
|
||
"other": {
|
||
"type": "ssvc",
|
||
"content": {
|
||
"timestamp": "2024-06-10T20:11:14.382101Z",
|
||
"id": "CVE-2024-5597",
|
||
"options": [
|
||
{
|
||
"Exploitation": "none"
|
||
},
|
||
{
|
||
"Automatable": "no"
|
||
},
|
||
{
|
||
"Technical Impact": "total"
|
||
}
|
||
],
|
||
"role": "CISA Coordinator",
|
||
"version": "2.0.3"
|
||
}
|
||
}
|
||
}
|
||
],
|
||
"title": "CISA ADP Vulnrichment",
|
||
"providerMetadata": {
|
||
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
||
"shortName": "CISA-ADP",
|
||
"dateUpdated": "2024-06-10T20:12:13.322Z"
|
||
}
|
||
},
|
||
{
|
||
"providerMetadata": {
|
||
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
||
"shortName": "CVE",
|
||
"dateUpdated": "2024-08-01T21:18:06.595Z"
|
||
},
|
||
"title": "CVE Program Container",
|
||
"references": [
|
||
{
|
||
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-151-02",
|
||
"tags": [
|
||
"x_transferred"
|
||
]
|
||
}
|
||
]
|
||
}
|
||
]
|
||
}
|
||
} |