Files
vuln-cve/data/2024/5xxx/CVE-2024-5040.json
T

218 lines
8.6 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-5040",
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"state": "PUBLISHED",
"assignerShortName": "icscert",
"dateReserved": "2024-05-16T23:41:33.314Z",
"datePublished": "2024-05-21T20:19:19.456Z",
"dateUpdated": "2024-08-01T21:03:10.607Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "LAquis SCADA",
"vendor": "LCDS",
"versions": [
{
"lessThanOrEqual": "4.7.1.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nThere are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory.\n\n"
}
],
"value": "There are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Path Traversal",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert",
"dateUpdated": "2024-05-21T20:19:19.456Z"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nLCDS recommends users update to <a target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\">version 4.7.1.371 or newer of LAquis SCADA.</a> which has been configured to resolve the reported path traversal issues.\n\n<br>"
}
],
"value": "LCDS recommends users update to version 4.7.1.371 or newer of LAquis SCADA. https://laquisscada.com/ which has been configured to resolve the reported path traversal issues."
}
],
"source": {
"advisory": "ICSA-24-142-01",
"discovery": "EXTERNAL"
},
"title": "LCDS LAquis SCADA Path Traversal",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"title": "CISA ADP Vulnrichment",
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"id": "CVE-2024-5040",
"role": "CISA Coordinator",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"version": "2.0.3",
"timestamp": "2024-05-22T14:29:23.705386Z"
}
}
}
],
"affected": [
{
"cpes": [
"cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*"
],
"vendor": "lcds",
"product": "laquis_scada",
"versions": [
{
"status": "affected",
"version": "*"
}
],
"defaultStatus": "unknown"
}
],
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-06-04T18:02:51.586Z"
}
},
{
"providerMetadata": {
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE",
"dateUpdated": "2024-08-01T21:03:10.607Z"
},
"title": "CVE Program Container",
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01",
"tags": [
"x_transferred"
]
}
]
}
]
}
}