Files
vuln-cve/data/2024/56xxx/CVE-2024-56835.json
T

242 lines
9.4 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"cveMetadata": {
"cveId": "CVE-2024-56835",
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"state": "PUBLISHED",
"assignerShortName": "siemens",
"dateReserved": "2025-01-03T10:21:11.980Z",
"datePublished": "2025-12-09T10:44:13.701Z",
"dateUpdated": "2026-01-13T09:43:49.860Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2026-01-13T09:43:49.860Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.17.0), RUGGEDCOM ROX MX5000RE (All versions < V2.17.0), RUGGEDCOM ROX RX1400 (All versions < V2.17.0), RUGGEDCOM ROX RX1500 (All versions < V2.17.0), RUGGEDCOM ROX RX1501 (All versions < V2.17.0), RUGGEDCOM ROX RX1510 (All versions < V2.17.0), RUGGEDCOM ROX RX1511 (All versions < V2.17.0), RUGGEDCOM ROX RX1512 (All versions < V2.17.0), RUGGEDCOM ROX RX1524 (All versions < V2.17.0), RUGGEDCOM ROX RX1536 (All versions < V2.17.0), RUGGEDCOM ROX RX5000 (All versions < V2.17.0). The DHCP Server configuration file of the affected products is subject to code injection. An attacker could leverage this vulnerability to spawn a reverse shell and gain root access on the affected system."
}
],
"affected": [
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX MX5000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX MX5000RE",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1400",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1500",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1501",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1510",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1511",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1512",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1524",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX1536",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "RUGGEDCOM ROX RX5000",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V2.17.0",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"baseScore": 8.8,
"baseSeverity": "HIGH"
}
},
{
"cvssV4_0": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"baseScore": 8.7,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-74",
"description": "CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection')",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-912274.html"
}
]
},
"adp": [
{
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2025-12-09T14:29:27.215015Z",
"id": "CVE-2024-56835",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2025-12-09T14:29:32.308Z"
}
}
]
}
}