226 lines
9.0 KiB
JSON
226 lines
9.0 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-52572",
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "siemens",
|
|
"dateReserved": "2024-11-14T12:25:53.336Z",
|
|
"datePublished": "2024-11-18T15:39:35.577Z",
|
|
"dateUpdated": "2024-12-10T13:54:08.165Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens",
|
|
"dateUpdated": "2024-12-10T13:54:08.165Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0005), Tecnomatix Plant Simulation V2302 (All versions < V2302.0018), Tecnomatix Plant Simulation V2404 (All versions < V2404.0007). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files.\r\nThis could allow an attacker to execute code in the context of the current process. (ZDI-CAN-24486)"
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Teamcenter Visualization V14.2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V14.2.0.14",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Teamcenter Visualization V14.3",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V14.3.0.12",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Teamcenter Visualization V2312",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2312.0008",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Teamcenter Visualization V2406",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2406.0005",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Tecnomatix Plant Simulation V2302",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2302.0018",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "Tecnomatix Plant Simulation V2404",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V2404.0007",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
|
|
"baseScore": 7.8,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV4_0": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
|
|
"baseScore": 7.3,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-121",
|
|
"description": "CWE-121: Stack-based Buffer Overflow",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824503.html"
|
|
},
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-645131.html"
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"id": "CVE-2024-52572",
|
|
"role": "CISA Coordinator",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"version": "2.0.3",
|
|
"timestamp": "2024-11-18T17:58:30.237542Z"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "tecnomatix_plant_simulation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "2302.0018",
|
|
"versionType": "custom"
|
|
},
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "2404.0007",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:a:siemens:tecnomatix_plant_simulation:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "tecnomatix_plant_simulation",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "2302.0018",
|
|
"versionType": "custom"
|
|
},
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "2404.0007",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2024-11-18T18:08:38.319Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |