Files
vuln-cve/data/2024/48xxx/CVE-2024-48010.json
T

194 lines
8.0 KiB
JSON

{
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-48010",
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"state": "PUBLISHED",
"assignerShortName": "dell",
"dateReserved": "2024-10-08T05:40:53.868Z",
"datePublished": "2024-11-08T03:01:01.903Z",
"dateUpdated": "2024-11-08T15:56:27.836Z"
},
"containers": {
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "PowerProtect DD",
"vendor": "Dell",
"versions": [
{
"lessThanOrEqual": "8.0.0.0",
"status": "affected",
"version": "7.7.1",
"versionType": "semver"
},
{
"lessThan": "7.13.1.10",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.10.1.40",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "7.7.5.50",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"datePublic": "2024-11-06T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
}
],
"value": "Dell PowerProtect DD, versions prior to 8.1.0.0, 7.13.1.10, 7.10.1.40, and 7.7.5.50, contains an access control vulnerability. A remote high privileged attacker could potentially exploit this vulnerability, leading to escalation of privilege on the application."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-284",
"description": "CWE-284: Improper Access Control",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell",
"dateUpdated": "2024-11-08T03:01:01.903Z"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000245360/dsa-2024-424-security-update-for-dell-pdsa-2024-424-security-update-for-dell-powerprotect-dd-vulnerabilityowerprotect-dd-vulnerability"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
},
"adp": [
{
"affected": [
{
"vendor": "dell",
"product": "powerprotect_data_domain_management_center",
"cpes": [
"cpe:2.3:o:dell:emc_data_domain_os:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:apex_protection_storage:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:-:*:*:*:virtual:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain:*:*:*:*:*:*:*:*",
"cpe:2.3:a:dell:powerprotect_data_domain_management_center:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"versions": [
{
"version": "7.13",
"status": "affected",
"lessThan": "7.13.1.10",
"versionType": "semver"
},
{
"version": "7.10",
"status": "affected",
"lessThan": "7.10.1.40",
"versionType": "semver"
},
{
"version": "7.7",
"status": "affected",
"lessThan": "7.7.5.50",
"versionType": "semver"
},
{
"version": "7.7.1",
"status": "affected",
"lessThanOrEqual": "8.0.0.0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-11-08T14:39:27.260279Z",
"id": "CVE-2024-48010",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-11-08T15:56:27.836Z"
}
}
]
}
}