"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"cveMetadata": {
"cveId": "CVE-2024-47904",
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"state": "PUBLISHED",
"assignerShortName": "siemens",
"dateReserved": "2024-10-04T16:15:00.392Z",
"datePublished": "2024-10-23T14:21:23.086Z",
"dateUpdated": "2024-10-23T18:00:15.305Z"
},
"containers": {
"cna": {
"providerMetadata": {
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens",
"dateUpdated": "2024-10-23T14:21:23.086Z"
},
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in InterMesh 7177 Hybrid 2.0 Subscriber (All versions < V8.2.12), InterMesh 7707 Fire Subscriber (All versions < V7.2.12 only if the IP interface is enabled (which is not the default configuration)). The affected devices contain a SUID binary that could allow an authenticated local attacker to execute arbitrary commands with root privileges."
}
],
"affected": [
{
"vendor": "Siemens",
"product": "InterMesh 7177 Hybrid 2.0 Subscriber",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V8.2.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
},
{
"vendor": "Siemens",
"product": "InterMesh 7707 Fire Subscriber",
"versions": [
{
"status": "affected",
"version": "0",
"lessThan": "V7.2.12",
"versionType": "custom"
}
],
"defaultStatus": "unknown"
}
],
"metrics": [
{
"cvssV3_1": {
"version": "3.1",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"baseScore": 7.8,
"baseSeverity": "HIGH"
}
},
{
"cvssV4_0": {
"version": "4.0",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"baseScore": 8.5,
"baseSeverity": "HIGH"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"lang": "en",
"cweId": "CWE-266",
"description": "CWE-266: Incorrect Privilege Assignment",
"type": "CWE"
}
]
}
],
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-333468.html"
}
]
},
"adp": [
{
"affected": [
{
"vendor": "siemens",
"product": "intermesh_7177_hybrid2.0_subscriber",
"cpes": [
"cpe:2.3:a:siemens:intermesh_7177_hybrid2.0_subscriber:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected",
"lessThan": "8.2.12",
"versionType": "custom"
}
]
},
{
"vendor": "siemens",
"product": "intermesh_7707_fire_subscriber",
"cpes": [
"cpe:2.3:a:siemens:intermesh_7707_fire_subscriber:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"versions": [
{
"version": "0",
"status": "affected",
"lessThan": "7.2.12",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"type": "ssvc",
"content": {
"timestamp": "2024-10-23T17:56:30.002922Z",
"id": "CVE-2024-47904",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"version": "2.0.3"
}
}
}
],
"title": "CISA ADP Vulnrichment",
"providerMetadata": {
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP",
"dateUpdated": "2024-10-23T18:00:15.305Z"
}
}
]
}
}