723 lines
30 KiB
JSON
723 lines
30 KiB
JSON
{
|
|
"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-47100",
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "siemens",
|
|
"dateReserved": "2024-09-18T17:02:51.295Z",
|
|
"datePublished": "2025-01-14T10:30:11.506Z",
|
|
"dateUpdated": "2025-01-14T14:33:39.216Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens",
|
|
"dateUpdated": "2025-01-14T10:30:11.506Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). The web interface of the affected devices is vulnerable to Cross-Site Request Forgery (CSRF) attacks. This could allow an unauthenticated attacker to change the CPU mode by tricking a legitimate and authenticated user with sufficient permissions on the target CPU to click on a malicious link."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1211C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1211C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1211C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1212FC DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1214FC DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215C AC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215C DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1215FC DC/DC/Rly",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIMATIC S7-1200 CPU 1217C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1214FC DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 AC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215 DC/DC/RLY",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215C DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "SIPLUS S7-1200 CPU 1215FC DC/DC/DC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V4.7",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:L/A:H/E:P/RL:O/RC:C",
|
|
"baseScore": 7.1,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
},
|
|
{
|
|
"cvssV4_0": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:P/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
|
|
"baseScore": 7.2,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-352",
|
|
"description": "CWE-352: Cross-Site Request Forgery (CSRF)",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-717113.html"
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"timestamp": "2025-01-14T14:32:19.691890Z",
|
|
"id": "CVE-2024-47100",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "partial"
|
|
}
|
|
],
|
|
"role": "CISA Coordinator",
|
|
"version": "2.0.3"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-01-14T14:33:39.216Z"
|
|
}
|
|
}
|
|
]
|
|
}
|
|
} |