"dataType": "CVE_RECORD",
|
|
"dataVersion": "5.1",
|
|
"cveMetadata": {
|
|
"cveId": "CVE-2024-38278",
|
|
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"state": "PUBLISHED",
|
|
"assignerShortName": "siemens",
|
|
"dateReserved": "2024-06-12T14:37:01.983Z",
|
|
"datePublished": "2024-07-09T12:05:07.958Z",
|
|
"dateUpdated": "2025-08-27T20:42:54.768Z"
|
|
},
|
|
"containers": {
|
|
"cna": {
|
|
"providerMetadata": {
|
|
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
|
|
"shortName": "siemens",
|
|
"dateUpdated": "2025-08-12T11:16:32.146Z"
|
|
},
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"value": "A vulnerability has been identified in RUGGEDCOM RMC8388 V5.X (All versions < V5.9.0), RUGGEDCOM RMC8388NC V5.X (All versions < V5.9.0), RUGGEDCOM RS416NCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416PNCv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416Pv2 V5.X (All versions < V5.9.0), RUGGEDCOM RS416v2 V5.X (All versions < V5.9.0), RUGGEDCOM RS900 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900G (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900GNC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RS900NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100 (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100NC(32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100P (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2100PNC (32M) V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2288NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300P V5.X (All versions < V5.9.0), RUGGEDCOM RSG2300PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488 V5.X (All versions < V5.9.0), RUGGEDCOM RSG2488NC V5.X (All versions < V5.9.0), RUGGEDCOM RSG907R (All versions < V5.9.0), RUGGEDCOM RSG908C (All versions < V5.9.0), RUGGEDCOM RSG909R (All versions < V5.9.0), RUGGEDCOM RSG910C (All versions < V5.9.0), RUGGEDCOM RSG920P V5.X (All versions < V5.9.0), RUGGEDCOM RSG920PNC V5.X (All versions < V5.9.0), RUGGEDCOM RSL910 (All versions < V5.9.0), RUGGEDCOM RSL910NC (All versions < V5.9.0), RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0), RUGGEDCOM RST916C (All versions < V5.9.0), RUGGEDCOM RST916P (All versions < V5.9.0). The affected products with IP forwarding enabled wrongly make available certain remote services in non-managed VLANs, even if these services are not intentionally activated. An attacker could leverage this vulnerability to create a remote shell to the affected system."
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RMC8388 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RMC8388NC V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS416NCv2 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS416PNCv2 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS416Pv2 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS416v2 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS900 (32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS900G (32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS900GNC(32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RS900NC(32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2100 (32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2100NC(32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2100P (32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2100PNC (32M) V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2288 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2288NC V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2300 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2300NC V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2300P V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2300PNC V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2488 V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG2488NC V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG907R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG908C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG909R",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG910C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG920P V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSG920PNC V5.X",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSL910",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RSL910NC",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RST2228",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RST2228P",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RST916C",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"vendor": "Siemens",
|
|
"product": "RUGGEDCOM RST916P",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "V5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"metrics": [
|
|
{
|
|
"cvssV3_1": {
|
|
"version": "3.1",
|
|
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
|
|
"baseScore": 6.6,
|
|
"baseSeverity": "MEDIUM"
|
|
}
|
|
},
|
|
{
|
|
"cvssV4_0": {
|
|
"version": "4.0",
|
|
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
|
|
"baseScore": 7.5,
|
|
"baseSeverity": "HIGH"
|
|
}
|
|
}
|
|
],
|
|
"problemTypes": [
|
|
{
|
|
"descriptions": [
|
|
{
|
|
"lang": "en",
|
|
"cweId": "CWE-266",
|
|
"description": "CWE-266: Incorrect Privilege Assignment",
|
|
"type": "CWE"
|
|
}
|
|
]
|
|
}
|
|
],
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html"
|
|
}
|
|
]
|
|
},
|
|
"adp": [
|
|
{
|
|
"metrics": [
|
|
{
|
|
"other": {
|
|
"type": "ssvc",
|
|
"content": {
|
|
"id": "CVE-2024-38278",
|
|
"role": "CISA Coordinator",
|
|
"options": [
|
|
{
|
|
"Exploitation": "none"
|
|
},
|
|
{
|
|
"Automatable": "no"
|
|
},
|
|
{
|
|
"Technical Impact": "total"
|
|
}
|
|
],
|
|
"version": "2.0.3",
|
|
"timestamp": "2024-07-24T17:16:47.980613Z"
|
|
}
|
|
}
|
|
}
|
|
],
|
|
"affected": [
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rmc8388:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rmc8388",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rmc8388nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rmc8388nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs416ncv2:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs416ncv2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs416pncv2:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs416pncv2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs416pv2:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs416pv2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs416v2:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs416v2",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs900:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs900",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs900g:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs900g",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs900gnc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs900gnc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rs900nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rs900nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2100:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2100",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2100nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2100nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2288:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2288",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2288nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2288nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2300:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2300",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2300nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2300nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2300p:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2300p",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2300pnc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2300pnc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2488:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2488",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg2488nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg2488nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg907r:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg907r",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg908c:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg908c",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg909r:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg909r",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg910c:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg910c",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg920p:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg920p",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsg920pnc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsg920pnc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsl910:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsl910",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rsl910nc:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rsl910nc",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rst2228:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rst2228",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rst2228p:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rst2228p",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rst916c:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rst916c",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
},
|
|
{
|
|
"cpes": [
|
|
"cpe:2.3:o:siemens:ruggedcom_ros_rst916p:*:*:*:*:*:*:*:*"
|
|
],
|
|
"vendor": "siemens",
|
|
"product": "ruggedcom_ros_rst916p",
|
|
"versions": [
|
|
{
|
|
"status": "affected",
|
|
"version": "0",
|
|
"lessThan": "5.9.0",
|
|
"versionType": "custom"
|
|
}
|
|
],
|
|
"defaultStatus": "unknown"
|
|
}
|
|
],
|
|
"title": "CISA ADP Vulnrichment",
|
|
"providerMetadata": {
|
|
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
|
|
"shortName": "CISA-ADP",
|
|
"dateUpdated": "2025-08-27T20:42:54.768Z"
|
|
}
|
|
},
|
|
{
|
|
"providerMetadata": {
|
|
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
|
|
"shortName": "CVE",
|
|
"dateUpdated": "2024-08-02T04:04:25.242Z"
|
|
},
|
|
"title": "CVE Program Container",
|
|
"references": [
|
|
{
|
|
"url": "https://cert-portal.siemens.com/productcert/html/ssa-170375.html",
|
|
"tags": [
|
|
"x_transferred"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
]
|
|
}
|
|
} |